ATTENTION:
Under any circumstances, make sure the hob is well ventilated and the air
inlet and outlet are not blocked. Ensure the hob is in good work state. As
shown below:
Note: The safety distance between the hob and the cupboard above should
be at least 760mm.
A (mm)
760
B (mm)
50 minimum
C (mm)
30 minimum
D
Air intake
E
Air exit 5mm
Weight and Dimensions are approximate. Because we continually strive to
improve our products, we may change specifications and designs without
prior notice.
Before you install the hob, make sure that
the work surface is square and level, and no structural members interfere
with space requirements.
the work surface is made of a heat-resistant material.
if the hob is installed above an oven, the oven has a built-in cooling fan.
the installation will comply with all clearance requirements and applicable
standards and regulations.
a suitable isolating switch providing full disconnection from the mains
power supply is incorporated in the permanent wiring, mounted and
positioned to comply with the local wiring rules and regulations.
The isolating switch must be of an approved type and provide a 3 mm air
gap contact separation in all poles (or in all active [phase] conductors if
the local wiring rules allow for this variation of the requirements). The
isolating switch will be easily accessible to the customer with the hob
installed.