Parkside PZM 2 B3 handleiding
Handleiding
Je bekijkt pagina 81 van 460

81GB/IE
NOTES:
o Before measurement:
– Disconnect all power at the
circuit to be tested.
– Discharge all capacitors
thoroughly.
Fuse replacement
m
DANGER: Risk of electric
shock! Use only a fuse
with the same specifications
(250 mA/600 V fast blow fuse).
1. Before opening the product:
– Switch off the product.
– Remove both test
probes[1][8] from any
circuit.
2. Loosen the screw
[]
of the
battery compartment
[]
cover.
Remove the battery compartment
cover.
3. Remove the batteries.
4. Loosen the 4 screws[9] from the
back of the housing. Remove the
back housing cover.
5. Replace the faulty fuse
[]
with
a new fuse of the same type
(250 mA/600 V fast blow fuse).
6. Reattach the back housing cover.
Tighten the 4 screws[9].
7. Put the batteries back into the
battery compartment.
8. Reattach the battery
compartment
[]
cover. Tighten
the screw
[]
.