NOTES:
Input impedance: approx.
10 MΩ
Frequency
range:
40 to
400 Hz
Response: Average
(calibrated
in RMS of
sine wave)
Max. allowable
input voltage: 600 V
Measuring DC current
1. Connect the black colour test
probe[1] to terminal: COM
[]
.
2. Turn the rotary knob[6] to
or .
3. Press SELECT[5] repeatedly
until
[]
is shown in the
display[2].
4. Turn off power at the circuit to be
tested. Discharge all capacitors.
5. Break the circuit path to be
tested.
6. Connect the black colour test
probe[1] and the red colour test
probe[8] in series with the circuit
to be tested.
7. Result:
The measured DC current and
the polarity of the red colour
test probe[8] (negative
polarity =
[]
)
are shown in the display[2].