Heat control
setting 2
If the heating level switch
2
is in this position, the
device produces a heat
output of 2000 W.
MIN position of the temperature control
MAX position of the temperature control
4.2 Setting the Temperature
Start the heater by using the heating level switch
2
to set the desired heat level.
Turn the temperature control
4
clockwise until
it stops. The control light
3
begins to illuminate.
When the desired temperature is reached, turn
the temperature control
4
counter-clockwise
until you hear an audible click. An integrated
thermostat will now automatically switch the
heating function on and off.
lowest temperature range
low to medium temperature range
medium to high temperature range
highest temperature range
Please note: The fan heater temporarily remains
very hot during the heating intervals. Please take
care when operating the fan heater.
The fan heater has angle adjustment. Turn the
rotary knobs
6
at the side to adjust the tilt.
4.3 Switching off the device
To avoid heat build-up in the fan heater, allow
the fan to run for approximately 30 seconds
afterwards.
Turn the heating level switch
2
to position "0".
Pull out the mains plug to disconnect the heater
from the mains supply, thus switching it off com-
pletely.
4.4 Overheating Protection
This fan heater is equipped with overheating
protection. If the fan heater overheats, it will switch
off automatically. The fan continues to run so that
rapid cooling is achieved. The fan heater will switch
on again automatically once it has cooled down
properly.
PLEASE NOTE: There is usually a reason
for overheating! It can indicate a fire
hazard!
Check whether the fan heater is giving off suffi-
cient heat: Is the fan heater covered or is it too
close to a wall or other obstruction? Is the grid
blocked in the front or at the back? Is the fan
blocked?
Rectify the problem if possible, or contact the
service hotline (see the section “Service”).
Even if you were unable to identify the cause, if
the overheating protection is triggered a second
time, you must switch off the fan heater and con-
tact the service hotline (see “Service” Section).
5. Troubleshooting
Fehler Mögliche
Ursache
Behebung
The fan
heater will
not switch
on.
The mains plug is
not plugged in.
Insert the mains
plug in the socket.
Socket delivering
no voltage.
Check the house
fuses.
The fan
heater
does not
heat up.
Heating level
switch
2
is not
switched on.
Set the heating
level switch
2
to the desired
operating mode.
Temperature con-
trol
4
is in the
MIN position.
Set temperature
control
4
to the
MAX position.
Faulty heating
element.
Notify customer
services.