22
supply cable must not be less
than 2x2,5mm².
• Unsuitable extension cable can
be dangerous. If an extension
cable is used it must be suitable
for outdoor use, and the con-
nection must remain dry and
be routed above the ground.
We recommend using a cable
drum that holds the plug at least
60mm above the ground.
• Wear sturdy footwear to protect
against electric shock.
Initial Operation
In keeping with current regulations
a pressure washer must never be
operated off the drinking water
mains supply without a controlla-
ble backow preventer. A suitable
backow preventer in conformity
with
EN 12729 type BA must be used.
Water that has passed through a backow
preventer is classied as undrinkable.
A backow preventer is available
from specialist retailers.
A system separator (check valve) prevents
the backow of water and detergent into
the drinking water pipeline.
• The pressure washer does not have a
water suction function and can only be
operated via the water pipe.
• Use a commercially available 1/2“
garden hose, at least 5m long, for
water supply. Do not exceed a length of
30m.
Setting up
1. Take the nozzle cleaning needle (14)
from the back pages of the instructions.
It is pinned to the instructions.
2. Slide the retaining bracket for the mains
connection cable (2) into the receptor
on the side of the pressure washer.
3. Screw the high-pressure connector for
the device (17) into the high-pressure
connection on the device (9).
4. Insert the high-pressure connector for the
spray gun (16) into the high-pressure
connection on the spray gun (19).
5. Connect the quick connector of the sup-
ply hose to the water connection cou-
pling (5) and the water connection with
lter insert (4) on the device.
6. Connect the jet pipe (12) to the spray
gun (13) by inserting and screwing it in.
7. Screw the adjustable at spray nozzle
(11) into the threaded connection (12a)
on the jet pipe (12).
8. To remove the at spray nozzle, un-
screw the at spray nozzle (11) from
the threaded connection (12a) on the jet
pipe.
The width of the jet can be increased by
turning the end of the nozzle to the left. To
reduce the width of the jet, turn the end of
the nozzle to the right.
Mains connection
The pressure washer you have acquired is
already tted with a mains plug. The pres-
sure washer must only be connected to an
earthed socket 230 V ~ 50 Hz.
Only operate the pressure washer
after all the above points have been
observed.