Turn On Delay Adjustment (all turn on modes)
You can delay the JCA100 turn on time, so it doesn’t turn on at the same instant as your other
components (or other JCA100s). This avoids AC power turn-on surges and brownouts that might trip
power strips or house wiring circuit breakers. If you’re fortunate enough to own more than two JCA100s,
select a different delay time for each unit. Turn the delay knob to the desired delay time from 0 seconds
(fully counterclockwise) to 12 Seconds (fully clockwise).
Turn On Threshold Adjustment (audio turn on mode only)
This knob sets the audio signal level required for the JCA100 to automatically turn on when the Turn On
Options switch is set to the Audio position. Fully counterclockwise is the most sensitive setting and
requires the least audio signal voltage. It is therefore labeled “Quieter.” Fully clockwise requires a higher
audio signal voltage and is therefore labeled “Louder.” In most systems the best results will be with the
Turn On Threshold knob set at or close to the Quieter position. In some situations, the JCA100 might
turn itself on if there is transient noise in your system, even when an audio signal is not present.
Similarly, the JCA100 might never shut off after the music stops, even after waiting more than 10 minutes.
In this case, try rotating the knob towards the Louder position.
12 V Input Jack
The JCA100 12 V input is a 3.5 mm jack (mono). To use the 12 V trigger, insert the trigger wire plug into
this jack and plug the wire’s other end into your preamplifier’s 12 V output jack. For your convenience we
have included a 12 V trigger wire with mono 3.5 mm plugs at both ends. The JCA100 12 V trigger circuit
draws a negligible 5 mA.
Note: If your preamplifier’s 12 V trigger output is bare terminals with + and – screws terminal instead of a
jack, you can cut the 3.5 mm plug off one end of the included trigger wire and attach the bare wires to
these terminals. The lead with the white stripe on it corresponds to the plug’s tip and the unmarked lead
corresponds to the sleeve of the plug. The trigger plug tip is + (positive) and its sleeve – (negative).
12 V Loop Out Jack
The Trigger Out jack lets you loop or “daisy-chain” the incoming trigger voltage to an additional JCA100 or
other component(s). The total load on your triggering device’s 12 V output is the sum of the trigger current
drawn by each of the components you plan to loop together. Check the maximum capacity of your
preamplifier’s trigger output so you do not overload it by connecting too many power amplifiers. Typical
preamp trigger outputs are rated to handle 50 mA to 100 mA.
3.5 mm and 2.5 mm Jacks
Some other Parasound power amplifiers and preamplifiers might use a 2.5 mm “sub-mini” (mono) trigger
jack. To use the JCA100 trigger with products that use a 2.5mm jack you will need a 3.5 mm to 2.5 mm
mono adapter for one of the plugs on the included trigger wire.