3. Insert the cleaning tool tip into the MTP* adapter as
shown.
NOTE: The FIBCCT Q
UICKNET Cassette MTP*
Cleaning Tool is keyed the same as a MTP* connector.
Insert the cleaning tool tip into the Q
UICKNET MTP*
adapter with the key of the cleaning tool tip matching
the keyway of the adapter.
4. Rotate the tape feeder wheel in the direction indicated
on the cleaning tool.
5. Remove the cleaning tool from the Q
UICKNET Cassette
MTP* adapter.
6. Repeat steps 3, 4 and 5 to ensure that any
contamination is removed. Replace the dust cap onto
the cleaning tool.
7. Clean the external connector as described in the
sections above.
8. Reinstall the external connector into the Q
UICKNET
Cassette MTP* adapter.
1. Grip the FMTPFCT, depressing the green lever of the
cleaning tool. The metal shutter on top of the cleaning
tool will open, exposing fresh cleaning material. Fresh
material is exposed each time the green lever is
depressed.
2. Position the female MTP* ferrule endface so that the
fiber tips are in contact with the cleaning material.
Wipe the ferrule endface along the cleaning material in
the direction shown on the cleaning tool.
3. Release the green lever of the cassette to cover the
cleaning material.
4. Repeat steps 1, 2 and 3 to ensure that any
contamination is removed.
PN433A PN433AOPERATING INSTRUCTIONS
© Panduit Corp. 2009
OPERATING INSTRUCTIONS
© Panduit Corp. 2009
Page 3 of 4
For Technical Support: www.panduit.com/resources/install_maintain.asp
Page 2 of 4
For Technical Support: www.panduit.com/resources/install_maintain.asp
SAFETY PRECAUTIONS
FMTPMFCT Instructions - Cleaning Male MTP* Connectors
1. LASER LIGHT PROTECTION
WARNING: LASER LIGHT IS INVISIBLE. THE INVISIBLE
LIGHT IS POWERFUL ENOUGH TO DAMAGE YOUR
EYES. SERIOUS DAMAGE TO THE RETINA OF THE EYE
IS POSSIBLE. NEVER LOOK INTO THE END OF A FIBER
THAT MAY HAVE A LASER COUPLED INTO IT. SHOULD
ACCIDENTAL EYE EXPOSURE TO LASER LIGHT BE
SUSPECTED, ARRANGE FOR AN EYE EXAMINATION
IMMEDIATELY.
2. CABLE HANDLING
WARNING: FIBER OPTIC CABLE CAN BE DAMAGED
BY EXCESSIVE PULLING, TWISTING, CRUSHING OR
BENDING STRESSES. CONSULT THE APPROPRIATE
SPECIFICATION SHEETS AS PROVIDED BY YOUR
CABLE VENDOR. ANY DAMAGE MAY DECREASE
OPTICAL PERFORMANCE.
Important Connector Cleaning Information
Clean all connectors prior to connection. Just like single fiber connectors, all multi-fiber connectors must be
properly cleaned prior to connection to ensure optimum optical performance is achieved. Although interconnect
cords and cable assemblies are shipped from the factory pre-cleaned and protected with a dust cover, the user
should never assume the ferrule or connector has not been contaminated. A contaminated endface may not meet
system insertion loss and reflectance requirements or may cause permanent damage to the fiber(s) when mated
to another connector. Therefore, it is recommended that each ferrule endface or tip be cleaned using this
procedure prior to connection.
FMTPFCT Instructions - Cleaning Female MTP* Connectors
*MTP is a registered trademark of US Conec Ltd. *MTP is a registered trademark of US Conec Ltd.
1. Grip the FMTPMFCT, depressing the green lever of
the cleaning tool. The metal shutter on top of the
cleaning tool will open, exposing fresh cleaning
material. Fresh material is exposed each time the
green lever is depressed.
2. Position the male MTP* ferrule endface so that the
fiber tips are in contact with the cleaning material.
Wipe the ferrule endface along the cleaning material in
the direction shown on the cleaning tool.
3. Release the green lever of the cassette to cover the
cleaning material.
4. Repeat steps 1, 2 and 3 to ensure that any
contamination is removed.
NOTE: The FMTPMFCT MTP* Male Fiber Cleaning
Tool is designed to provide clearance for the
connector's guide pins allowing the fiber tips to contact
the cleaning material.
FIBCCT Instructions - Cleaning QuickNet Cassette MTP* Connectors
1. Remove the external connector or dust cover from the
Q
UICKNET Cassette MTP* adapter.
2. Remove the dust cap from the FIBCCT.