Finger Removal and Replacement
Part Number(s): PR2VRFK6, PR2VRFK6WH, PR2VRFK15, PR2VRFK15WH
To Remove Fingers:
Step 1:
Using a flathead screwdriver, gently
pry up plastic latches in (4) places
indicated while at the same time applying
forward pressure to the finger section.
Latch
location
Latch
location
Latch
location
Latch
location
Fingers removed for clarity
Step 2:
Push out the finger section
toward the inside of the manager.
Fingers removed for clarity
To Replace Fingers:
Align finger mounting tabs
with mounting slots on manager.
Place the finger mounting tabs
under the steel flange on the
manager, aligning them with the
mounting slots,then push the
finger section toward outside of
the manager until an audible
“click” is heard.
Note: Because the part is long,
the installer may have to push the
finger section out in several spots
before it is secured. Light tapping
with a dead blow hammer may be
used to fully seat the fingers.

Bekijk gratis de handleiding van Panduit AR4P, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.

Productinformatie

MerkPanduit
ModelAR4P
CategorieNiet gecategoriseerd
TaalNederlands
Grootte3635 MB

Caratteristiche Prodotto

Frame typeOpen frame
MateriaalStaal
Rack-montageJa
Afmetingen (B x D x H)515.9 x 1066.8 x 213.9 mm