INOXPAN S.L.
V3000 N ECO:
Should be installed with a Ø200mm conduit, a different diameter will affect the performance
of the motor, reducing its suction capacity, increasing noise produced as well as causing
other problems.
The recommended length of the conduit between the hood and the motor is 6
-
8 m
maximum, a greater distance will reduce the motor's suction capacity, while a shorter
distance will increase the noise of the hood, if the latter case in inevitable, we recommend
the use of soundproofing elements.
It is recommended that the conduit from the hood to the motor is without sharp angles, as
they will reduce the suction capacity of the motor. If they are inevitable, try to ensure they
are not too close to the inlet or outlet of the motor (at least 0.5m away). Do not use elbow
joints of less than 90º, or place one after another, the minimum recommended distance
between them is 1m, and try to make them as open as possible.
The maximum total length of the conduit from the hood to the exterior should be 12 linear
metres, not counting elbow joints (one elbow joint is equivalent to 2.5 linear metres), any
longer and the suction capacity of the motor will be reduced.
EN INSTALLATION
21

Bekijk gratis de handleiding van Pando P-401, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.

Productinformatie

MerkPando
ModelP-401
CategorieAfzuigkap
TaalNederlands
Grootte8513 MB

Caratteristiche Prodotto

Soort bedieningKnoppen
Kleur van het productRoestvrijstaal
Ingebouwd displayNee
Breedte1200 mm
Diepte520 mm