Menus
For installer
Menu Default Setting Setting Options / Display
Sterilization: Boiling temp.
65 °C
Set boiling
temperatures for
sterilize the tank.
Sterilization: Ope. time (max)
0:10
Set sterilizing time
(in hours and minutes)
7 Installer setup Service setup
7.1
Pump maximum speed
To set the maximum speed of
the pump.
Setting the fl ow rate, max. duty and operation
ON/OFF of the pump.
Flow rate: XX:X L/min
Max. Duty: 0x40 ~ 0xFE,
Pump: ON/OFF/Air Purge
7.2
Pump down
To set the pump down
operation.
Pump down operation
ON
7.3
Dry concrete
To dry the concrete (fl oor, walls,
etc.) during construction.
Do not use this menu for any
other purposes and in period
other than during construction
Edit to set the temperature of dry concrete.
ON / Edit
Edit
Stages: 1
Temperature: 25 °C
Heating temperature
for drying the
concrete.
Select the desired
stages: 1 ~ 10,
range: 1 ~ 99
ON
Confi rm the setting temperatures of dry
concrete for each stage.