Panasonic CS-CU-Z12RKR handleiding

12 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 9 van 12
English
9
To learn more...
The human activity sensor will also scan for area of heat source and movement in a room.
Detection area
• Based on area activeness horizontal air ow direction will adjust either x
at predetermined position or swing left/right periodically.
• The human activity sensor performance is in uenced by indoor unit
location, movement speed, temperature range, etc.
120º
7m
• The human activity sensor may:
- mistakenly detect an object with heat source & movement similar to human, such as pets, etc.
- mistakenly detect as non-heat source & movement if a human stays motionless for certain period of time.
• Do not place large objects near the sensor and keep away heating units or humidi er from the sensor’s detection
area. They may cause sensor malfunction.
i AUTO-X
Low activity Normal activity
Human
Mode
Set
temperature
High activity Absent
i AUTO-X ; Fast cooling to maximum of 4 hours, the unit continue to provide cooling comfort according human
presence and activity detection.
i AUTO-X
+1 °C
+2 °C
-1 °C
Operation conditions
Use this air conditioner under the following temperature range.
DBT : Dry bulb temperature
WBT : Wet bulb temperature
Temperature (°C)
Indoor Outdoor
DBT WBT DBT WBT
COOL
Max. 32 23 46 26
Min. 16 11 5 -
HEAT
Max. 30 - 24 18
Min. 16 - -15 -