6.5 Transmission Formats
This is the format that the computer will send to the display to execute commands.
The format for this command transmission is as follows:
- Data Length: 13 byte
Ex) <STX>001PWRWOFF0<ETX> (Set ID: 1, “Power Off” Send)
- STX: Start of Text (0x0f)
- ID1 ~ ID3: Set ID (001~100)
- CM1 ~ CM3: Command (PWR, MIN, MUT, RML, KPL…)
- R/W: Read/Write
- DA1 ~ DA3: Data (Values)
- IND: Index
- ETX: End of Text (0x0d)
STX ID1 ID2 ID3 CM1 CM2 CM3 R/W DA1 DA2 DA3 IND ETX
0x0F ‘0’ ‘0’ ‘1’ ‘P’ ‘W’ ‘R’ ‘W’ ‘O’ ‘F’ ‘F’ 0x00 0x0D