6
CHARGE PROGRAM
Protection
BMS reset 
2
1
Charger will not proceed without user interaction.
LED #2 REVERSE POLARITY: Lights when the battery connections 
are incorrect. The charger is electronically protected so no damage will 
result, and the output will remain disabled until the connections are 
corrected.
BMS RESET: for batteries with a battery management system (BMS) that 
protects against deep discharge.  Disconnect the charger from mains supply. 
Wait for LED #1a/1b to go out. Reconnect to mains supply. A special BMS 
reset pulse is delivered for up to 5 seconds. The program should continue to 
STEP 4. 
STEP 1
Low Volt Start 
≥ 0.5V
V
Battery voltage check - OptiMate Lithium automatically activates 
if connected battery voltage is at least 0.5 Volt.
STEP 2
TEST before 
charge
STEP 3
Temperature
check
TEST LEDs
6 : GREEN
7 : YELLOW
8 : RED
TEST
8
7
6
TEST LEDs #6/7/8 indicate the battery condition prior to charging. Consult the 
table  on page 2 to match TEST LED indication to an estimated state of 
charge percentage (SOC%). 
During the test: 
OPTIMIZE minimum charge time is set according to the test result, varying 
between 10 minutes for a battery with 80% or higher state of charge to 120 
minutes 
for a battery with 40% or less state of charge. 
Ambient temperature is measured to determine charge voltage parameters. 
LOW TEMPERATURE WARNING - LED #8 (red) flashing: The temperature 
measured at OptiMate Lithium is below -20 degrees Celcius or 4 degrees 
Fahernheit, below the safe charging AND discharging zone for LiFePO
4
batteries. 
Charging commences after 10 seconds. 
8
7
6
90            100%603010% 
13.3V        13.6V+   13.13V13.00V12.80VV
8
7
7
6
0
0.5V
STEP 4
ULTRA LOW 
VOLT SAVE
STEP 5
LOW VOLT SAVE
STEP 6
TEST - cell 
damage
LED #3 : RED
3
IMPORTANT: If this mode engages read the section VERY FLAT 
NEGLECTED BATTERIES on the preceding page.  
This mode engages
 if the battery was more than 90% discharged / voltage 
is below 12.8V safeTº: Charge current is automatically adjusted according 
to voltage and ambient temperature measured during the test.         
VERY LOW VOLTAGE SAVE for batteries between 0.6V and 8.8V :  
Current starts at 125mA and will increase to 325mA depending on charge 
progress. If the voltage did not rise above 8.8V within 2 hours, charging will 
be suspended and the TEST LED #8 (red) will flash, indicating the battery 
may have suffered permanent damage or a professional assessment is 
required.  
LOW VOLTAGE SAVE for batteries between 8.9V and 12.8V (16V): 
Maximum current is set to 1.25A. The battery's charge acceptance is 
monitored for unusual behaviour. 
A healthy LiFePO
4
 battery will progress to CHARGE mode within 4 hours, 
otherwise charging will be suspended and TEST LED #8 (red) will flash, 
indicating the battery may have suffered permanent damage or a 
professional assessment is required. 
10
OptiMate
maintenance
9
 TEST after
CHARGE
1
Low Volt
Start (0.5V)
2
 TEST before
charge
3
Temperature
check
4
 Ultra LOW 
VOLT SAVE
5
LOW VOLT 
SAVE /
cellmonitoring