Optimate 7 Select handleiding
Handleiding
Je bekijkt pagina 6 van 48

4
STEP 1
Selection
14.4V &
14.7V
charge
modes.
PS - (Power
supply
mode.
LED #1a / 1b / 2:
Confirms AC power
supply to the
charger and
selected mode.
13.6V
6
7
8
7
8
12.2V
8
Push and release the SELECT pushbutton. The mode selection changes
when the button is released.
SAVE (#3), CHARGE (#4) and/or TEST (#6,7,8) LEDs flash twice to
confirm the new selection is in memory. Selection remains even if AC
power is lost.
CHARGE MODES: LED #1a = 14.4V. LED #1b = 14.7V.
A charge mode automatically activates and will proceed to STEP 3 if
connected battery voltage is at least 0.5 Volt.
With battery connected, if a new selection is made or AC power is lost &
again recovered, the charge program will restart from STEP 3.
14.7V selection - This higher charge voltage is only suitable for certain
premium AGM or sealed deep cycle / traction 12V lead-acid batteries.
Other 12V lead-acid batteries will be overcharged and may suffer
permanent damage. Confirm battery charge voltage requirement before
making the 14.7V selection. If you are not sure, select 14.4V. It is safe
for any 12V lead-acid battery.
PS (Power Supply): LED #2.
With 14.4V or 14.7V charge program in operation, press the button (3
sec.) until LED #2 lights. A fixed 13.6V is delivered, with up to 8Amps of
current available.
LED indication during Power Supply mode:
LED #6, #7, #8 = voltage at 13.6V, current draw below 8 Amps.
LED #7 & #8 = voltage below 13.6V, current draw exceeds 8 Amps.
LED #8 = voltage below 12.2V, battery SOC < 25%.
To turn off PS mode and return to charging, press the button (3 sec.)
until LED #2 turns off and the previously selected CHARGE mode (14.4V /
14.7V) re-activates.
WARNING: PS mode (13.6V) remains active even if disconnected
from battery. Do not touch clips together.
STEP 2
Protection
LED #1a / 1b / #2:
flash on/off.
No operation
without user
interaction.
REVERSE POLARITY / incorrect battery connection: The charger is
electronically protected so no damage will result, and the output will
remain disabled until the connections are corrected.
Following correction charge modes 14.4V & 14.7V automatically activate
and will proceed to STEP 3. PS mode - see below.
PS (power supply) LED #2 flashing ON/OFF: Indicates that a fault
condition such as reverse connected battery, a short circuit or overload
was detected, or AC power was interupted during PS mode.
If necessary correct the fault condition, then push and release the
SELECT pushbutton. Output is restored when LED #2 (PS) turns full on.
STEP 3
Preparing
to charge
Immediately following connection to a battery there may be a 1-2 second delay before charging
progresses, during which time battery State Of Charge (SOC %) and ambient temperature (°C / °F) is
measured to determine charge requirement and duration of the test in STEP 9.
STEP 4 & 5
SAVE
State of
charge:
less than
50%
LED #3 : RED
1
4
.
4
V
1
4
.
7
V
P
o
w
e
r
S
u
p
p
l
y
14.4V
14.7V
24-724-7
PS
14.4V
14.7V
12V
13.6V
5
4
3
1a
1b
2 8
6
7
STEP 4
TURBO SAVE
STEP 5
PULSE SAVE
The battery SAVE mode engages if the battery is less than 50% charged OR
voltage is between 0.5 to 12.4 Volt. Charge time: 15min to 2hrs.
TURBO SAVE : The battery was diagnosed as sulphated, unable to accept
or hold charge - Current is limited to 0.4A and voltage is allowed to rise
towards 16V to check for active vehicle electronics, if detected, STEP 5
immediately engages. Otherwise voltage may briefly rise as high as 22V to
overcome sulphation within the battery.
IMPORTANT: Read section VERY FLAT NEGLECTED BATTERIES below.
With voltage limited to 14.4V / 14.7V (as selected) current is delivered in
pulses to prepare the battery to accept normal charge and increase its state
of charge towards 50%.
1
4
.
4
V
1
4
.
7
V
P
o
w
e
r
S
u
p
p
l
y
14.4V
14.7V
24-724-7
PS
14.4V
14.7V
12V
13.6V
5
4
3
1a
1b
2
8
6
7
Bekijk gratis de handleiding van Optimate 7 Select, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.
Productinformatie
| Merk | Optimate |
| Model | 7 Select |
| Categorie | Niet gecategoriseerd |
| Taal | Nederlands |
| Grootte | 7780 MB |