Optimate 6 Select handleiding
Handleiding
Je bekijkt pagina 7 van 44

5
STEP 6
CHARGE
State of 
charge: 
50% - 75%
 LED #4 :BLUE
1a
1b
2
3
4
5
6
7
8
1 2 3
Power
Supply
13.6V
12.2V
13.6V
PS
14.4V
14.7V
13.6V
12V     6A  
GOLD
12V
6A
select
optimate1.com
/om6select
AUTOMATIC BATTERY CHARGER 
+ TESTER + MAINTAINER
FOR 12V LEAD-ACID BATTERIES
24-7
P
o
w
e
r
S
u
p
p
l
y
1
4
.
4
V
1
4
.
7
V
12V
Engages if the battery state of charge is 50% or higher or once 
the battery has been sufficiently recovered during STEP 5. 
The ampmatic™ charge current monitoring and control program 
automatically determines the most efficient rate of charge current 
for the connected battery, according to its state of charge, state of 
health, and electrical storage capacity. 
STEP 7
OPTIMIZE 
(pulsed 
absorption / 
final charge)
State of 
charge: 
75% - 100%
LED #5 : BLUE
1a
1b
2
3
4
5
6
7
8
1 2 3
Power
Supply
13.6V
12.2V
13.6V
PS
14.4V
14.7V
13.6V
12V     6A  
GOLD
12V
6A
select
optimate1.com
/om6select
AUTOMATIC BATTERY CHARGER 
+ TESTER + MAINTAINER
FOR 12V LEAD-ACID BATTERIES
24-7
P
o
w
e
r
S
u
p
p
l
y
1
4
.
4
V
1
4
.
7
V
12V
Engages when the voltage has reached 14.4V (14.7V) for the 
first time during STEP 6. 
The ampmatic™ current control program now delivers pulses of 
current to equalise the individual cells within the battery and 
optimize charge level. 
Charge time during this step varies between 10 and 120 minutes, 
influenced by initial battery State Of Charge and health as measured 
in STEP 3, and current draw by connected circuitry.   
For safety reasons there is an overall charge time limit of 72 
hours for STEPS 4 to 7. 
STEP 8
TEST after 
CHARGE
LED #6 : GREEN
1a
1b
2
3
4
5
6
7
8
1 2 3
Power
Supply
13.6V
12.2V
13.6V
PS
14.4V
14.7V
13.6V
12V     6A  
GOLD
12V
6A 
select
optimate1.com
/om6select
AUTOMATIC BATTERY CHARGER 
+ TESTER + MAINTAINER
FOR 12V LEAD-ACID BATTERIES
24-7
P
o
w
e
r
S
u
p
p
l
y
1
4
.
4
V
1
4
.
7
V
12V
TEST after charge : Delivery of current to the battery is 
interrupted for 30 minutes** to allow the program to determine 
the battery’s  ability to retain charge. 
** IF charging started in SAVE mode (LED #3) the voltage retention 
test is extended to 12 hours to confirm battery health.
LED #6 (green) will remain on for batteries able to hold 90% or 
higher state of charge (SOC%), otherwise the TEST result is 
adjusted lower in real time according to the measured battery 
voltage. Consult the table on page 2 to match TEST LED indication to 
an estimated state of charge percentage (SOC%). 
Also read section “NOTES ON TEST RESULTS” below. 
STEP 9
OptiMATE
24-7
Maintain
LED #6 / 7 / 8  
1a
1b
2
3
4
5
6
7
8
1 2 3
Power
Supply
13.6V
12.2V
13.6V
PS
14.4V
14.7V
13.6V
12V     6A  
GOLD
12V
6A
select
optimate1.com
/om6select
AUTOMATIC BATTERY CHARGER 
+ TESTER + MAINTAINER
FOR 12V LEAD-ACID BATTERIES
24-7
P
o
w
e
r
S
u
p
p
l
y
1
4
.
4
V
1
4
.
7
V
12V
For batteries with a 
good state of health LED 
#6 (green) will remain 
on.
Exception: STD wet cell 
batteries with filler caps 
have a lower fully 
charged voltage: LED 
#6 remains on together 
with LED #7. 
MAINTENANCE CHARGE: LED #6 / 7 / 8 steady on 
according to state of charge measured during STEP 8.  
Float voltage setting: 13.6V nominal at 20°C (68°F) The float 
voltage is inversely regulated according to ambient 
temperature; i.e., voltage is increased at lower temperature, 
decreased at higher temperature. 
Adjustment: -0.004V / cell / °C above or below 20°C (68°F). 
OptiMate 24-7 maintenance mode consists of 30 minute float 
charge periods followed by and alternating with 30 minute ‘rest’ 
periods, during which there is no charge delivered. This “50% duty 
cycle” prevents loss of electrolyte in sealed batteries and minimizes 
gradual loss of water from the electrolyte in batteries with filler caps, 
optimizing the service life of irregularly or seasonally used batteries.
During “float charge” a continuous LOW CURRENT PULSE IS 
DELIVERED TO PREVENT SULFATION, further extending battery 
power and life. 
If the OptiMate senses the battery has suddenly lost charge the 
program will revert back to STEP 7. 
VERY FLAT NEGLECTED BATTERIES: If the battery is deeply discharged (and possibly sulfated), remove 
from the vehicle or equipment and inspect the battery before connecting the charger for a recovery 
attempt.  
The charger’s TURBO recovery mode cannot engage if it senses that the battery is still connected to a 
circuit which effectively offers a lower electrical resistance than the battery on its own. However, if the 
deep-discharged battery is not removed for recovery, neither battery nor vehicle or equipment electronics will 
be damaged. Pay particularly close attention to the following  A battery left deep-discharged for an 
Bekijk gratis de handleiding van Optimate 6 Select, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.
Productinformatie
| Merk | Optimate | 
| Model | 6 Select | 
| Categorie | Niet gecategoriseerd | 
| Taal | Nederlands | 
| Grootte | 7171 MB | 