Installation
Important: Please keep the installation procedure below. Improper or no
operation may result if the start-up sequence is not correctly followed.
Step 1
Carefully unpack the contents of the shipping group.
Step 2
Plug and fasten the 5V power adapters to the +5V DC jack on the rear side of
converter. Ensure the Power LED is ON (Blue).
Step 3
Please, check if the maximum resolution of the display is WUXGA
(1920x1200). Otherwise, follow the instructions for Self-EDID Programming
Procedure on page 1-5.
Step 4
Connect any video sources to designated input ports over cable. (e.g. Use
DVI cable to connect DVI source to DVI IN) If the source is active, status LED
(Blue) for each input will be turned on.
Note1: OMVC-200 is designed to detect the first incoming video signal and
convert to 1 fiber DVI signal or decide a priority input by pre-
programming as DVI, VGA, Component, S-Video, and Composite in an
order when all signals are connected and turned on.
Step 5
Connect the OPTICAL OUT to 1-fibe DVI receiver, DVFX-100-R over multi-
mode SC-SC optical fiber.
Step 6
Plug DVFX-100-R to DVI input port of display.
1-3 Installation
Note1: The maximum extension length by multi-mode fiber is 500 meters.
Note2: It is recommended NOT to use any intermediate cable or adapter in
between to avoid undesirable performance degradation.
Figure 1 Connection Diagram of OMVC-200
1-4 Installation
VGA Source
DVI Source
S-video /
Composite video
Source
Component
video Source
DVFX-100
Rx
Remote
DVI Display
Up to WUXGA
OMVC-200
One (1) Optical Fiber