09 OCI603KZCOMUser Manual
Preparing the Cut-Out
Cut-Out Dimensions:
Model Width (W) Depth (D)
OCI603KZCOM 560mm 490mm
The bench cut-out should be made as per the relevant
cutout dimensions shown above. It is most critical that the
cut-out chosen corresponds to your cooktop model.
A minimum of 50mm clearance space around the cut out
must be met when installing the appliance.
To ensure clearances to combustible surfaces observe
the minimum distance requirements, follow the relevant
information shown in the above table, corresponding to
your model.
Be sure the thickness of the work surface is at least
30mm. Please select heat-resistant and insulated work
surface material (Wood and similar fibrous or hygroscopic
material shall not be used as work surface material unless
impregnated) to avoid the electrical shock and larger
deformation caused by the heat radiation from the hotplate.
Under all circumstances, make sure the cooktop is well
ventilated and the air inlet and outlet are not blocked.
Ensure the cooktop is in good working state.
A barrier must be installed to prevent accidental contact
with the cooktop base, where the base of the cooktop is
accessible from below (i.e. Inside a cupboard, etc.).
A minimum clearance of 50mm must be maintained
between the base and the barrier. This barrier may be made
of any non-combustible, rigid material.
Barrier protection is not necessary if the product is installed
above an underbench oven or similar appliance and/or if
the cupboard construction is such that the underside of the
cooktop is not accessible.
Ensure that the power supply cable is not accessible through
cupboard doors or drawers.
Ensure that there is adequate flow of air from outside the
cabinetry to the base of the cooktop.
The isolating switch is easily accessible by the customer.
WARNING: Do not use any kind of silicon sealant to seal the
appliance against the benchtop. This will make it difficult
to remove the appliance, which must be accessible for the
service agent to perform any necessary repairs in the future.
Clamps and screws are supplied with your cooktop.
Fit the pull down clamps supplied to ensure that the cooktop
cannot move after installation. Refer to the diagram shown
below, and the relevant instructions.
The safety distance between the sides of the cooktop and
the inner surfaces of the worktop should be at least 3mm.
Installation Instructions
W
D
seal
min. 3mm