5 - TECHNICAL DATA
For the technical data listed below, consult the characteristic data plate afxed to the product.
Power supply voltage
Maximum power absorbed
Maximum current absorbed
Cooling capacity
Refrigerant gas
Protection rating of the casings
Max. operating pressure
Hermetically sealed appliance.
ContainsuorinatedgreenhousegasR32
UNICO Air INVERTER 20SF-20HP EVA
Dimensions (Width x Height x Depth) ..........................mm 980 x 490 x 160
Weight (without packaging) ..........................................kg 37
UNICO Air INVERTER 25SF-25HP EVA
Dimensions (Width x Height x Depth) ..........................mm 980 x 500 x 160
Weight (without packaging) ..........................................kg 38
OPERATING LIMIT
CONDITIONS
INDOOR
TEMPERATURE
OUTDOOR
TEMPERATURE
Maximum operating temperatures in
cooling mode
DB 35°C - WB 24°C DB 43°C - WB 32°C
Minimum operating temperatures in
cooling mode
DB 18°C DB -10°C
Maximum operating temperatures in
heating mode
DB 27°C DB 24°C - WB 18°C
Minimum operating temperatures in
heating mode
- - - DB -15°C