Changing settings from the operator panel
- 122 -
Item
Factory
default
setting
Description
Maintenance Counter Disable Set whether or not to add a Maintenance Report (non-
resettable Counter and non-resettable Consumable
Replacements) to [Usage Report].
[Disable]: Print the resettable Counter and resettable
Consumable Replacements in [Usage Report].
[Enable]: In addition to the resettable Counter and
resettable Consumable Replacements, the Maintenance
Report (non-resettable Counter and non-resettable
Consumable Replacements) is also printed together in
[Usage Report].
It is displayed when [Print Statistics] - [Usage Report] is set
to [Enable].
Reset Main Counter Execute Reset the main counter.
It is displayed when [Print Statistics] - [Usage Report] is set
to [Enable].
Reset Supplies Counter Execute Reset the replacement counter of consumables.
The maintenance counter is not reset.
It is displayed when [Print Statistics] - [Usage Report] is set
to [Enable] and [Maintenance Counter] is set to [Enable].
Account Lockout Lockout Enable Set whether or not to prohibit new authentication for a
certain period of time when authentication with a password
for Print Statistics has failed consecutively.
Lockout Condition 5 times Set the conditions for lockout.
Value range: 1 - 10 times (in increments of 1 time)
It is displayed when [Lockout] is set to [Enable].
Lockout Period 5 minutes Set the period for lockout.
Value range: 1 minute, 5 minutes, 10 minutes, 15 minutes,
30 minutes, and 60 minutes
It is displayed when [Lockout] is set to [Enable].
Password Policy
Minimum Length
10 or 1*
Set the minimum length of the password.
Use Uppercase On or Off* Set whether the password contains at least one upper-case
letter.
Use Lowercase On or Off* Set whether the password contains at least one lower-case
letter.
Use Symbol
Off
Set whether the password contains at least one symbol.
Use digit
Off
Set whether the password contains at least one digit.
Change Password - Set a new password required to enter the Print Statistics
menu.
It is displayed when [Print Statistics] - [Usage Report] is set
to [Enable].
Menus (Calibration)
Item
Factory default
setting
Description
Fuser Temp Adjust
0
Adjust the fuser unit temperature.