IMPORTANT USER INFORMATION
Before use operators shall be provided with information, instruction and training for the use of the machine and the sub-
stances for which it is to be used, including the safe method of disposing of material collected.
The dust container has to be emptied when necessary, but also after every time used.
The manufacturer, or an instructed person, shall perform a technical inspection at least annually, consisting of, for example,
inspection of lters for damage, air tightness of the machine and proper function of the control mechanism.
For user servicing, the machine shall be dismantled, cleaned and serviced, as far as is reasonably practicable, without
causing risk to the maintenance sta and others. Suitable precautions include decontamination before dismantling,
provision for local ltered exhaust ventilation where the machine is dismantled, cleaning of the maintenance area and suit-
able personal protection.
This vacuum cleaner has a lamp that illuminates when air velocity drops below a < 20 m/s, which
indicates that the bag must be changed.
All lters including the bag must be undamaged and in correct position before this machine can be used safely.
Extraction from electric power tools can be controlled by an integral automatic electronic switch-on / shut-o - Auto Start
Feature
WARNING:
1. This machine must only be operated by suitably trained and authorised personnel.
2. This machine or its accessories must not be modied.
3. The machine must not be stored or used in a wet environment.
4. Do not allow the dust collection bag to become so full as to reduce the eective pick-up of the vacuum.
(Lamp will illuminate at preset air velocity levels < 20 m/s).
5. Only use the dust collection bag once.
6. This machine must only be repaired by suitably trained and authorised personnel.
7. Only use genuine Numatic International Ltd spare parts, for repairs.
8. This machine must not be installed as a xed extraction system or run unattended.
9. Do not re-use the essential lter element after removal out of the machine.
Operators should observe any safety regulations appropriate to materials being handled.
This machine is for dry use only.
PREPARATION FOR USE
Unpack and identify each item of equipment from the delivery note.
Check that the details given match the information on the “rating plate” mounted on the head assembly.
Installation / Removal / Disposal of the dust bag/ cartridge lter.
The dust bag/ cartridge lter holding the dust and debris must be removed and renewed by authorised personnel only,
wearing appropriate personal protective equipment, in a specied de-contamination area.
Never operate without the full ltration system in place.
Remove the cloth lter in the drum. Remove the dust bag from the hose ange inside the drum and seal the dust bag hole.
Place the dust bag cartridge lter inside an impervious plastic bag and seal the bag.
Dispose of the plastic bag, depending on contamination, in an appropriate manner.
Label Explained
1 M type Vacuum Cleaner
2 Caution, debris contained inside the vacuum cleaner could be hazardous to health
3 Caution!
4 Read instructions before use
Warning
This machine contains dust hazardous to health. Empting and maintenance operations, including removal of the dust bag,
must only be carried out by trained personnel, who are familiar with the machine and
wearing suitable personal protective equipment. DO NOT operate without the full ltration system tted.
For M class machines, outside of the machine should be decontaminated by vacuum cleaning methods and wiped clean or
treated with sealant before being taken out of a hazardous area.