Energy labelling
NIBESupplier
ERS S40-400Model
Average: -37.9
Cold: -74.8
Warm: -14.2
kWh/(m
2
year)
Specific energy consumption (SEC)
A
Energy efficiency class
RVU, BidirectionalDeclared typology
Variable speed driveType of drive
RegenerativeType of heat recovery system
82Thermal efficiency of heat recovery
460m
3
/hMaximum air flow rate
178WElectric power input of the fan drive at maximum
flow rate
51dBSound power level (LWA)
0.089m
3
/sReference flow rate
50PaReference pressure difference
0.25W/m
3
/hSpecific power input (SPI)
Local demand control (0.85)Control factor and control typology
Internal: 3.2
External: 0.6
%External leakage rates
See user manual.Information about filter warning
See section General ventilation connections on page 14.Information about supply/exhaust grilles in the
facade
See section Recovery on page 5.
This installer manual can also be accessed at nibe.eu.
Information about pre-/disassembly
275kWh/yearThe annual electricity consumption
Average: 4,413
Cold: 8,633
Warm: 1,996
kWh
prim/year
Annual heating saved, kWh primary energy per year
NIBE ERS S40-400Chapter 10 | Technical data26