Neptun NPHA-E 3600 handleiding
Handleiding
Je bekijkt pagina 13 van 168

13
GB
15. Troubleshooting guide
Faults Cause Remedy
Motor fails to start up -  No mains voltage
-  Pump rotor blocked -thermostat
switched off
- Check voltage
-  Dismantle and clean pump
No intake -  Intake valve not in water
-  Pump chamber without water
connection
-  Air in intake line air-tight
- Intake valve leaks
- Strainer (intake valve) blocked
-  Max. suction height exceeded
- clean
- Remove the coarse filter with the
non-return valve, then fill water
into the pump housing.
- Make sure intake line is close
- Clean intake valve
- Clean strainer
- Check suction height
Inadequate delivery rate -  Suction height too high
- Coarse filter dirty
- Water level falling rapidly
- Pump performance diminishedby
contaminants part
-  Check suction height
- clean
- Place the suction hose at a
deeper level
- Clean pump and replace wearing
Thermostat switches pump off -  Motor overloaded - friction
caused by foreign substances
too high
-  Dismantle and clean pump.
Prevent intake of foreign
substances (filter)
Anleitung_NPHA_E_3600_SPK7__  31.10.2016  11:30  Seite 13