Neptun NPHA-E 3600 handleiding

168 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 13 van 168
13
GB
15. Troubleshooting guide
Faults Cause Remedy
Motor fails to start up - No mains voltage
- Pump rotor blocked -thermostat
switched off
- Check voltage
- Dismantle and clean pump
No intake - Intake valve not in water
- Pump chamber without water
connection
- Air in intake line air-tight
- Intake valve leaks
- Strainer (intake valve) blocked
- Max. suction height exceeded
- clean
- Remove the coarse filter with the
non-return valve, then fill water
into the pump housing.
- Make sure intake line is close
- Clean intake valve
- Clean strainer
- Check suction height
Inadequate delivery rate - Suction height too high
- Coarse filter dirty
- Water level falling rapidly
- Pump performance diminishedby
contaminants part
- Check suction height
- clean
- Place the suction hose at a
deeper level
- Clean pump and replace wearing
Thermostat switches pump off - Motor overloaded - friction
caused by foreign substances
too high
- Dismantle and clean pump.
Prevent intake of foreign
substances (filter)
Anleitung_NPHA_E_3600_SPK7__ 31.10.2016 11:30 Seite 13

Bekijk gratis de handleiding van Neptun NPHA-E 3600, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.

Productinformatie

MerkNeptun
ModelNPHA-E 3600
CategorieNiet gecategoriseerd
TaalNederlands
Grootte18527 MB