You can solve many common problems easily, saving you the cost of a possible service call. Try the suggestions below to see if you can solve the
problem before calling the service centre.
Problem
Possible cause
Treatment
The heater does not operate,even
when it is plugged in and the
switch, thermostat are switched on
The plug is loose, bad connection
Pull out the plug, check the connection of the plug
and socket. Then connect again.
No power in socket outlet
Insert the plug in a proper socket
The heating element glowing
The input voltage is too high or too low
Use power supply according to the rating on the
label
The air inlet grill is blocked
Keep the heater far way from articles like curtain,
plastic bag, paper and other things which can
cover the inlet or can be easily cover on the air
inlet
The appliance didn’t heat up, or
only ventilator worked
The switch was not put at heating setting
Turn the switch to heat setting
The thermostat operated
Turn the thermostat and listen if there is
open/close voice. If there is no click and the
thermostat is not damaged, the heater will
automatic switch on when the appliance cooled
down
The self-resetting cut-out operated
Turn the heater off and inspect the blockage of
inlet or outlet. Disconnect the plug and wait at
least 10 minutes for the protection system to
reset before attempting to restart the heater.
Abnormal noise
The appliance is not stands upright
Put the heater on a level surface
Disposal
Waste electrical production should not be disposed of with household waste. Please recycle where facilities exist. Check with your
Local Authority or retailer for recycling advice.
Environmental Protection
Model identifier(s): 90-065
Item
Symbol
Value
Unit
Item
Unit
Heat output
Type of heat input, for electric storage local space heaters only (select one)
Nominal heat output
Pnom
2
kW
Manual heat charge control with integrated thermostat
[no]
Minimum heat output
(indicative)
Pmin
kW
Manual heat charge control with room and/or outdoor temperature
feedback
[no]
Maximum
continuous heat
output
Pmax
2
kW
Electronic heat charge control with room and/or outdoor
temperature feedback
[no]
Auxiliary electricity consumption
Fan assisted heat output
[no]
At nominal heat
output
elmax
N/A
kW
Type of heat output/room temperature control (select one)
At minimum heat
output
elmin
N/A
kW
Single stage heat output and no room temperature control
[no]
In standby mode
elSB
N/A
W
Two or more manual stages, no room temperature control
[no]
With mechanic thermostat room temperature control
[yes]
With electronic room temperature control
[no]
Electronic room temperature control plus day timer
[no]
Electronic room temperature control plus week timer
[no]
Other control options (multiple selections possible)
Room temperature control, with presence detection
[no]
Room temperature control, with open window detection
[no]
With distance control option
[no]
With adaptive start control
[no]
With working time limitation
[no]
With black bulb sensor
[no]
Contact details:
Grupa Topex Sp. z o. o. Sp. k. Ul. Pograniczna 2/4, 02-285 Warszawa
Remark:
For electric local space heaters, the measured seasonal space heating energy efficiency ηs cannot be worse than the declared value at
the nominal heat output of the unit.
Model identifier(s): 90-066
Item
Symbol
Value
Unit
Item
Unit
Heat output
Type of heat input, for electric storage local space heaters only (select one)
Nominal heat output
Pnom
3
kW
Manual heat charge control with integrated thermostat
[no]
Minimum heat
output (indicative)
Pmin
1.
5
kW
Manual heat charge control with room and/or outdoor temperature
feedback
[no]