MSW -SPP44-075 handleiding
Handleiding
Je bekijkt pagina 7 van 39

12 13
12 13
Rev. 28.02.2022
Rev. 28.02.2022
• It will be easier for your customer service assistant
to determine the source of the problem if you give
a detailed and precise description of the problem.
The more detailed your information, the better
customer service will be able to solve your problem
rapidly and eciently!
CAUTION: Never open the device without the authorization
of your customer service. This can lead to a loss of warranty!
TROUBLESHOOTING
Problem Possible reason Solution
The device
does not
start.
Overcurrent
circuit breaker
has tripped.
Remedy the cause
of the circuit breaker
tripping. Wait for
the motor to cool
down. Reset the
circuit breaker to its
original position.
No power Make sure the power
cable is connected
properly.
Damaged
engine or power
cable.
Call your agent or
qualied technician.
The device
starts but
does not
pump/
pumps
only a little
water.
Water feed
clogged.
Remove the
blockage.
Leaking water
connections.
Seal the connections.
Insucient
water level in
the borewell.
Check the water
level. There pump
should be at least 2
m below the water
surface.
Water delivery
head too height.
Install the pump
in accordance
with its technical
specication.
EN
Failure to observe the following guidelines may result in
a device fault or sudden malfunction:
• Install the pump in a well in a vertical position.
• Before lowering the pump into a borewell, make sure
the sludge has been cleaned out.
• Do not use the pump to pump dirty water (e.g.
contaminated with oil, particles, abrasive particulate
matter, etc.).
• Do not use the pump for salt water, corrosive
substances, ammable liquids, etc.
• Do not use with water which exceeds 35 °C.
• If the pump is installed in a borewell which is too
wide, it will lead to insucient cooling and the device
will overheat. In this case, a cooling jacket should be
installed.
• Do not start the pump before it is submerged in
water. "Dry" operation results in permanent damage
to the pump. The pump should be fully submerged,
and the water surface should be at least 2 m above
the water discharge holes.
• Attach the power cable to the delivery pipe (using
cable ties for example) at least every 2 m to avoid the
cable braking under its own weight.
• Use a non-return valve to protect the pump against
returning water impact.
• Before lowering the pump into a new borewell
ensure sludge, silt and sand have been thoroughly
cleaned out.
• Using the pump for pumping water with a high
mineral content is not recommended. Water with
a high mineral content may result in the appearance
of deposits on the pump housing, preventing correct
cooling of the motor which in turn might lead to
overheating and damage the motor.
• Do not use the pump if the ambient temperature is
below zero. Frozen water will damage the device and
the water delivery system to the surface.
• Do not obstruct the water outlet when in use.
• Use a rope (standard nylon preferably) attached to
the pump handles to lift, carry and lower the pump
into a borewell.
• The product should be used under the supervision of
a person with appropriate knowledge in terms of its
use and operation.
Borewell submersible pump electrical wiring diagram:
STOP
• Connect the device power cable in accordance with
the electrical diagram included in these instructions.
• The control panel should be located in a place
protected against water ingress. Do not operate the
device with wet hands.
• Extensions to the power lead, if required, should be
hermetically sealed and performed by a person with
appropriate qualications.
• Do not use the power cable to carry the device.
• The pump should be earthed. Use a residual current
device up to 30mA in the electrical system.
• Disconnect from power source immediately if the
pump malfunctions or the power cable insulation is
damaged.
• Do not switch the pump on when standing in water
or barefoot on a wet, electrically conductive surface.
To switch on the pump set the On/O switch to the On
position.
If the overcurrent circuit breaker is tripped by a short circuit,
overheating, etc., once the problem has been resolved (the
cause of overcurrent circuit breaker tripping), release the
circuit breaker by pressing the circuit breaker button on the
control panel housing.
Dismantling the pump
In areas where temperatures drop below zero, dismantle
the pump for the winter season and store it in accordance
with the guidelines in "transport and storage" section.
To dismantle the pump:
• Set the On/O switch to the O ("0") position;
• Disconnect the pump from the power source;
• Extract the pump from the borewell using a steel
or a dierent secure rope attached to the pump
handles;
• Disconnect the water delivery pipe from the pump;
• Empty any water remaining in the pump by turning
it upside down;
• Once the pump the pump is dry, it is ready to be
stored safely.
TRANSPORTATION AND STORAGE
Shaking, crashing and turning the device upside down
should be prevented when transporting it. Store it in
a properly ventilated location with dry air and without any
corrosive gas. Store the device in ambient temperatures
above zero in a horizontal position. If the pump has
been stored for more than a few days, ensure the device
functions properly before installing it again.
CLEANING AND MAINTENANCE
• Always unplug the device before cleaning it.
• Use cleaner without corrosive substances to clean
each surface.
• Clean organic deposits from the device after every
use with a stream of clean water and a soft cloth.
• Store the unit in a dry, cool place, free from moisture
and direct exposure to sunlight.
REGULAR CONTROL OF THE DEVICE
Check regularly if the device is damaged. In case of
damage, please stop using it immediately and contact
customer service for solving the problem
What to do in case of a problem?
Please contact customer service and prepare the following
information:
• Invoice number and serial number (the latter is to be
found on the technical plate on the device).
• If necessary, take a picture of the damaged, broken
or defective part.
black
blue
brown
yellow-green
EN
Bekijk gratis de handleiding van MSW -SPP44-075, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.
Productinformatie
| Merk | MSW |
| Model | -SPP44-075 |
| Categorie | Niet gecategoriseerd |
| Taal | Nederlands |
| Grootte | 7886 MB |