MSW -GE 18000 POWER handleiding
Handleiding
Je bekijkt pagina 36 van 324

EN
Air
filter
Control x x
Replacemen
t
x
Fuel drop
filter
Cleani
ng
x
In line fuel
filter
Exchan
ge
X (if needed
or dirty
replace
earlier)
Spark plug
Inspec
tion
and
cleanin
g
x
Fuel
hoses
from the
fuel tank
Inspectio
n and
cleaning
Every 2 years
Adjustment of valve
clearance
x
Cleaning the head
x
a) Pull the mains plug and let the unit cool down completely before cleaning,
adjusting or replacing accessories and when the unit is not in use. Wait
until the rotating parts stop.
b) Use only non-corrosive cleaning agents for cleaning the surfaces.
c) Store the unit in a dry and cool place protected from moisture and direct
sunlight.
d) Do not spray the unit with a stream of water or immerse it in water.
e) Make sure that no water enters through the ventilation openings in the
casing.
f) Clean the ventilation openings with a brush and compressed air.
g) Perform regular inspections of the unit checking technical fitness and any
damages.
h) Use a soft cloth for cleaning.
i) Replace the engine oil regularly with fresh oil.
To change engine oil, it is best done when the oil is warm because it is
thinner and flows more easily. CAUTION: oil directly after work is hot - risk
of burns!