MSolutions MS-41Q handleiding
Handleiding
Je bekijkt pagina 21 van 25

21
support@m4sol.com | www.m4sol.com
MS-41Q USER GUIDE
Commands (cont.)
25
RHPOS
3
Show window horizontal position
SVPOS N M
3
Set window vertical position
window N=1~4,
1: A, 2: B, 3: C, 4: D
position M=0~90
RVPOS
3
Show window vertical position
SWIN N M
[M M M]
3
Set window on/off.
Use N=0 to set all windows in one
command when using custom layout
window N=0~4,
1: A, 2: B, 3: C, 4: D
0: all windows
M=0~1,
0: off, 1: on
Command Description Parameter
RWIN
3
Show window states
SPRI N M
Set window layer priority.
Window A is fixed to bottom and cannot
be changed.
window N=1~4,
1: A, 2: B, 3: C, 4: D
layer priority M=2~4,
2 = layer 3
3 = layer 2
4 = upper
RPRI
3
Show window layer priority
SRECALL 1~10 Set layout
1 = layout A,
2 = layout B,
3 = custom 1,
4 = custom 2,
5 = custom 3,
6 = custom 4,
7 = custom 5,
8 = custom 6,
9 = custom 7,
10 = custom 8
SROTATE 0~4
1
Set video rotation.
Select full screen mode before rotation
0 = rotate off,
1 = L90,
2 = R90,
3 = Flip on,
4 = Flip off
RROTATE Show video rotation state
SIPM 0/1
4
Set IP mode 0=DHCP, 1=static,
RIPM Show IP mode
SIPADD N M X Y
5
Set IP address
192 168 1 202
N=0~255, M=0~255, X=0~255,
Y=0~255
RIPADD Show IP address
SMAADD N M X Y
5
Set subnet mask 255 255 255 0
Bekijk gratis de handleiding van MSolutions MS-41Q, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.
Productinformatie
| Merk | MSolutions |
| Model | MS-41Q |
| Categorie | Niet gecategoriseerd |
| Taal | Nederlands |
| Grootte | 3614 MB |