3.4.1 Specifications of Connection Pipe
3.4 Refrigerant Piping Connection
Model
External diameter (inch)
Gas pipe Liquid pipe
MDUCC15024/MDUCC15036
3/4 in 3/8 in
MDUCC15048/MDUCC15060
3.4.2 Piping Preperation
NOTE: If you are installing your A-Coil with the optional MRCOOL Quick-Connect
®
Line Set, please
skip forward to the insallation instructions for the line set on pg. 8. Once the line set installation is
complete, return to step 3.5 Condensate Removal and continue installation from there.
Solder Connection
If connecting piping with solder, make sure that any cuts made to the piping are round, burr free
(use a reamer), cleaned, and at a perfect 90° angle. Make sure the line set size matches the service
valve connector. DO NOT crimp the service valve connector if the piping is of a smaller diameter.
Failure to follow these guidelines could result in refrigerant leaking from the piping. Refer to the
illustrations below.
Oblique Rough Warped
90°
Pipe
Reamer
Point down