MKTI-1014 Timer meccanico industriale - Cod. 493933776 English
SAFETY INSTRUCTIIONS
Incorrect installation and improper use of this device may result in serious electric shock injuries, including risk of death. Installation must be carried
out by qualied technical personnel, ensuring the power supply is disconnected for the entire duration of the operation. Read these instructions carefully
before installation and use. The device is intended for domestic use, in indoor environments, and protected from weather conditions. Before use, verify
compatibility with the technical specications of the device it is connected to, particularly in terms of operating voltage and permissible load. Do not use with
medical equipment or safety devices. Do not connect to devices that, in the event of malfunction or incorrect operation, could lead to hazardous situations (e.g.,
hydraulic pumps, puriers, etc.). The device is designed for installation inside electrical panels, with upstream dierential and circuit breaker protection devices
and proper grounding: do not use in other congurations and do not expose it to the elements. Do not handle the device with wet hands. Do not disassemble or modify the device: such
actions void the safety requirements and the warranty. Ensure it cannot be tampered with by children or individuals with reduced cognitive and/or motor abilities, and that it is out of
reach of pets. In case of malfunction, immediately disconnect the device and contact a qualied technician. Disconnect the power and have the device inspected by qualied personnel
if it shows deformation, discoloration, cracks in the casing, emission of smoke and/or vapors and/or unpleasant odors, or unusual sounds. Do not perform installation or connections
while the system is powered. Do not use to control SELV (Safety Extra Low Voltage) devices. To set the time, rotate only the minute hand—this may be done repeatedly—until the desired
setting is reached. Ensure that connected cabling has a smooth and unobstructed path. Provide adequate ventilation to the device, particularly by ensuring that connected cables
follow a linear and unobstructed route. Do not use in environments with humidity or temperature levels dierent from those specied in the technical data. Keep these instructions for
future reference.
TECHNICAL DATA
Operating voltage
220-240 V AC 50/60 Hz
Program duration
24 hours
Protection class
second EN 60730-1
Self-consumption
0,5 W
Minimum interval
15 minuti
Degree of protection
IP20
Overvoltage protection
4 KV 1,2/50 uS
Load current with cos ϕ = 1
16 A @ 250 V AC
Operating temperature
-10° - +50° C
Contact
Changeover switch
Load current with cos ϕ = 0.6
4 A @ 250 V AC
Battery operated @ 230 V
200 hours
Precision
< ±1 s/day
Minimum load current
100 mA @ 24 V AC
Contact width
3 mm
Installation
DIN EN 60715
Incandescent lamp load
1.000 W
Contact width
3 mm
INSTALLATION
CONNETCTIONS
DIMENSION
The device must be installed on a DIN rail by
hooking the lower part and pressing the upper
part into place.
To remove it, use a at-head screwdriver to lift
the locking clip: the device will be released from
the rail and can be removed.
When viewed from the front with
the labels upright, the device has
the contacts in the same position
as shown in the diagram.
L = Permanent phase
N = Neutral
1 = At the load
2= Clean contact
SETTING
Time setting: The time dial must be rotated only from top to bottom until the indicator aligns with the current time. Time activation: Each segment
corresponds to the quarter-hour marked on the time dial, which in turn aligns with the hour number shown on the left. Move the green levers to the
left to switch the load on during the corresponding quarter-hour, or to the right to keep it o. Manual override: The switch at the top left has two
positions.: = Timed activation according to the programming.
I = Continuous ON: the programming is retained, but the load remains permanently on until a dierent mode is selected.
MAINTENANCE: The device does not require maintenance in terms of replacing consumable parts or scheduled servicing. In general, occasional cleaning and removal of dust
buildup will ensure long-term reliability. Maintenance operations must be performed only with the device disconnected from the power supply, and it should be reconnected only after
ensuring it is completely dry. Do not use aggressive cleaners or abrasive sponges; usually, a damp cloth is suicient.
According to Directive 2012/19/EU of the European Parliament and of the Council, of 4 july 2012, on waste electrical and electronic equipment (WEEE), the presence of
the crossed-out bin symbol indicates that this appliance is not to be considered as urban waste: its disposal must therefore be carried out by separate collection. Disposal
in a non-separate manner may constitute a potential harm to the environment and health. This product can be returned to the distributor when purchasing a new device.
Improper disposal of the appliance constitutes misconduct and is subject to sanctions by the Public Security Authority. For further information, contact the local
administration responsible for environmental matters.
Made in China
Melchioni S.p.A.
Via Pietro Colletta 37, 20135 Milano, Italy | www.melchioni-ready.com

Bekijk gratis de handleiding van MKC MKTI-1014, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.

Productinformatie

MerkMKC
ModelMKTI-1014
CategorieThermostaat
TaalNederlands
Grootte444 MB