In the following cases, stop using the air conditioner and consult your dealer.
• Whenwaterleaksordripsfromtheindoorunit.
• Whentheoperationindicatorlampblinks.
• Whenthebreakertripsfrequently.
• TheremotecontrolsignalisnotreceivedinaroomwhereanelectronicON/
OFFtypeuorescentlamp(inverter-typeuorescentlamp,etc.)isused.
• OperationoftheairconditionerinterfereswithradioorTVreception.Anampli-
ermayberequiredfortheaffecteddevice.
When an abnormal sound is heard.
• Whenanyrefrigerantleakageisfound.
WHEN YOU THINK THAT
TROUBLE HAS OCCURRED
Symptom Explanation & Check Points
Timer
Weeklytimerdoesnotoperate
according to settings.
Is the ON/OFFtimerset? Page 8
• Transmitthesettinginformationoftheweekly
timer to the indoor unit again. When the informa-
tionissuccessfullyreceived,alongbeepwill
sound from the indoor unit. If information fails to
bereceived,3shortbeepswillbeheard.Ensure
information is successfully received.
Page 9
• When a power failureoccurs and the main
powerturnsoff,theindoorunitbuilt-inclockwill
beincorrect.Asaresult,theweeklytimermay
notworknormally.
Be sureto place theremotecontroller where
the signal can be received by the indoor unit.
Page5
The unit starts/stops the opera-
tion by itself.
• Istheweeklytimerset? Page 9
Others
Thealuminumnontheedgeof
the heat exchanger is discolored
as if it is burnt.
• Thisisthecoatingresindiscoloredduetoweld-
ingheatwhen the heatexchangerwasbeing
produced.
The operation of the air conditioner is not the
cause of the discoloration.
It affects neither the performance of the heat
exchanger nor the use of the air conditioner.
1
OperatebyCOOLmodewiththehighesttemperature
setorFANmodefor3to4hours.Page6
This dries the inside of the unit.
• Moistureintheairconditionercontributes tofavorableconditionsfor
growthoffungi,suchasmold.
2
Press
to stop the operation.
3
Turnoffthebreakerand/ordisconnectthepowersup-
ply plug.
4
Remove all batteries from the remote controller.
When using the air conditioner again:
1
Cleantheairlter.Page11
2
Checkthattheairinletandoutletoftheindoorand
outdoorunitsarenotblocked.
3
Checkthattheearthisconnectedcorrectly.
4
Refertothe“PREPARATIONBEFOREOPERATION”,
andfollowtheinstructions.
Page5
WHEN THE AIR CONDITIONER IS NOT
GOING TO BE USED FOR A LONG TIME
Electrical work
• Provideanexclusivecircuitforthepowersupplyoftheairconditioner.
• Besuretoobservethebreakercapacity.
If you have any questions, consult your dealer.
INSTALLATION PLACE AND
ELECTRICAL WORK
To prevent the effects
ofauorescentlamp,
keepasfarapartas
possible.
wall,etc.
Inverter-type
uorescentlamp
Keepaspace
to prevent
the picture
distortion or
the noise.
1m
or
more
Radio
100
mmor
more
TV
Cordless
phone or
Portable
phone
3mormore
1m
or more
The installation location of the outdoor
unitshould be at least 3 m awayfrom
the antennas for TV sets, radios, etc. In
areaswherethereceptionisweak,pro-
videgreaterspacebetweentheoutdoor
unit and the antenna of the affected
device if operation of the air conditioner
interfereswithradioorTVreception.
200mmormore
For the optimum ef-
ciency
andtoextend
the life time of using,
the outdoor unit
should be installed in
awell-ventilateddry
place.
Installation place
Avoid installing the air conditioner in the following places.
Where there is much machine oil.
Salty places such as the seaside.
• Wheresuldegasisgeneratedsuchashotspring,sewage,wastewater.
• Whereoilissplashedorwheretheareaislledwithoilysmoke(suchascook-
ingareasandfactories,inwhichthepropertiesofplasticcouldbechanged
anddamaged).
• Wherethereishigh-frequencyorwirelessequipment.
• Wheretheairfromtheoutdoorunitairoutletisblocked.
Where the operation sound or air from the outdoor unit bothers the house next
door.
• Themountingheightofindoorunit1.8mto2.3misrecommended.Ifitis
impossible, please consult your dealer.
• Donotoperatetheairconditionerduringinteriorconstructionandnishing
work,orwhilewaxingtheoor.Beforeoperatingtheairconditioner,ventilate
theroomwellaftersuchworkisperformed.Otherwise,itmaycausevolatile
elementstoadhereinsidetheairconditioner,resultinginwaterleakageor
scatteringofdew.
• Theindoorunitmustbeinstalledinroomswhichexceedtheoorspacespeci-
ed.Pleaseconsultyourdealer.
For Wi-Fi interface
Do not use the Wi-Fi interface nearby the medical electrical equipment or peo-
plewhohaveamedicaldevicesuchasacardiacpacemakeroranimplantable
cardioverter-debrillator.
It can cause an accident due to malfunctions of the medical equipment or
device.
• Thisequipmentshouldbeinstalledandoperatedwithaminimumdistanceof
20cmbetweenthedeviceandtheuserorbystanders.
• DonotusetheWi-Fiinterfacenearbyotherwirelessdevices,microwaves,
cordless phones, or facsimiles.

Bekijk gratis de handleiding van Mitsubishi MSZ-EF22-50VGKD, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.

Productinformatie

MerkMitsubishi
ModelMSZ-EF22-50VGKD
CategorieAirco
TaalNederlands
Grootte4259 MB