Although the heating system does not require annual maintenance, care must be taken to ensure
that the system is not damaged. Never pierce the floor. Puncture of an electrically conductive
element with a nail or screw may cause the fuse to trip, which will cut off the power supply to the
entire system, and in extreme cases, this situation may lead to the risk of electric shock.
Heating mats should not be placed under permanent furniture. This could trap heat and
potentially cause localized overheating.
Please inform all professionals dealing with any repairs or renovations, if they work in the area
of the installed heating system, about the heating system used. These persons should read the
information contained in the installation and operating instructions before starting work.
Unfamiliarity with the heating system used and failure to comply with the information contained
in its manual may result in a risk of electric shock.
Heating mats should not be placed under permanent furniture. This could trap heat and
potentially cause localized overheating.
Please inform all professionals dealing with any repairs or renovations, if they work in the area
of the installed heating system, about the heating system used. These persons should read the
information contained in the installation and operating instructions before starting work.
Unfamiliarity with the heating system used and failure to comply with the information contained
in its manual may result in a risk of electric shock.
Be sure to measure the system resistance as instructed on the following pages. The tolerance of
mat resistance results is +10% / -5%. If an incorrect measurement value is found at any stage,
further work should be refrained from.
Heating mats are designed for floor mounting. It is forbidden to mount them on walls or ceilings.
Do not cut or shorten heating cables. The backing mesh can be cut to fit the mat to the required
shape. The possibilities of cutting the mesh, depending on the given situation, are presented on
page 26.
The heating mat cannot be combined in one circuit with other heating devices.
The materials used for the floor covering must have a thermal resistance of 80°C.
It is unacceptable to install the heating mat without a regulator, directly to the power supply. It is
strictly forbidden to connect the mat directly to the socket/socket.
Heating mats must not overlap or touch each other. The distance between the heating cables
should be at least 10 cm.
During installation work, wear shoes with flat and rubber soles only. If possible, avoid stepping
on heating cables.
All installation materials must be suitable for underfloor heating.
Turn off the main power supply during installation work.
A heating system based on electric heating mats cannot be installed at temperatures below 5°C,
During the installation, follow the previously made project. If the concept changes during
installation, it must be clearly indicated in the project.
The rolled up heating mat must not be connected to the power supply.
ATTENTION!
B I U R O @ M I S S I O N A I R . P L S E R W I S @ M I S S I O N A I R . P L W W W . M I S S I O N A I R . P LT E L . ( + 4 8 ) 7 9 7 4 5 1 1 1 1
missionair
M A - 1 6 0 H E A T I N G M A T A S S E M B L Y M A N U A L
E N

Bekijk gratis de handleiding van Mission Air MA-160, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.

Productinformatie

MerkMission Air
ModelMA-160
CategorieNiet gecategoriseerd
TaalNederlands
Grootte5335 MB