DESIGN
The first and very important stage is the design of the entire heating system.
Mission Air® MA-160 heating mats can be used as:
The only essential heating system in the room.
In this case, make sure that the power generated by the system will exceed the heat loss in the room.
In order for the system to be efficient and comfortable for the household members, it is assumed that
it should cover at least 2/3 of the room area.
For the main source of space heating, the use of temperature controllers with programmable
functions is strongly recommended. Choosing such a solution will allow us to plan the operation of
the system for individual scenarios. Correctly selected settings will ensure that the system is
subsequently virtually maintenance-free and energy consumption remains as low as possible.
An additional, supporting heating system in the room.
This solution is recommended when we want to achieve the warm floor effect we like so much,
without giving up the current main source of heating.
In this case, you can consider using simpler, manual temperature controllers, usually based on
readings from a floor temperature sensor.
As a rule of thumb, an electric underfloor heating system is simply a large underfloor radiator.
Therefore, it is definitely not allowed to limit its work by using permanent furniture on its surface.
Places where there are or are to be buildings or other permanent elements adjacent to the floor (e.g.
a thick carpet or a bed for our pet) should be subtracted from the heating mats arrangement plan.
This principle should also be kept in mind when rearranging or renovating a given room in the
future. When designing the system, the mandatory distance to the walls of min. 5cm.
If you share an apartment with electric heating mats installed, be sure to inform the people who will
be staying there. When selling a property, also inform new buyers about the heating system used.
We do not use electric heating mats in areas particularly exposed to moisture. Such places include,
above all, the interiors of: shower cabins, bathtubs or swimming pools.
In rooms with an increased degree of moisture, it is necessary to use temperature regulators with a
housing tightness class of at least IP21, and its location should be at least 60 cm from the most
humid zones described above. We do not use heating mats directly under hanging bathroom
fittings. A distance of 10 cm from places of permanent installation or fittings should be assumed.
B I U R O @ M I S S I O N A I R . P L S E R W I S @ M I S S I O N A I R . P L W W W . M I S S I O N A I R . P LT E L . ( + 4 8 ) 7 9 7 4 5 1 1 1 1
missionair
M A - 1 6 0 H E A T I N G M A T A S S E M B L Y M A N U A L
E N