3
When battery pack is not in use, keep it away
from other metal objects, like paper clips, coins,
keys, nails, screws or other small metal objects,
that can make a connection from one terminal
to another. Shorting the battery terminals together
may cause burns or a re.
Under abusive conditions, liquid may be ejected
from the battery; avoid contact. If contact ac-
cidentally occurs, flush with water. If liquid
contacts eyes, additionally seek medical help.
Liquid ejected from the battery may cause irritation
or burns.
Do not use a battery pack or tool that is dam-
aged or modied. Damaged or modied batteries
may exhibit unpredictable behavior resulting in re,
explosion or risk of injury.
Do not expose a battery pack or tool to re or
excessive temperature. Exposure to re or tem-
perature above 265°F (130°C) may cause explosion.
Follow all charging instructions and do not charge
the battery pack or tool outside the temperature
range specied in the instructions. Charging
improperly or at temperatures outside the specied
range may damage the battery and increase the
risk of re.
SERVICE
Have your power tool serviced by a qualied
repair person using only identical replacement
parts. This will ensure that the safety of the power
tool is maintained.
Never service damaged battery packs. Service
of battery packs should only be performed by the
manufacturer or authorized service providers.
SPECIFIC SAFETY RULES FOR
DRAIN CLEANERS
Only grasp the rotating cable with gloves rec-
ommended by the manufacturer. Latex or loose
tting gloves or rags can become wrapped around
the cable and may result in serious personal injury.
Do not allow the cutter to stop turning while the
cable is turning. This can overstress the cable and
may cause twisting, kinking, or breaking of the cable
and may result in serious personal injury.
One person must control both the cable and the
switch. If the cutter stops rotating, the operator must
be able to turn the tool o󰀨 to prevent the cable from
twisting, kinking, and breaking.
Use latex or rubber gloves inside the gloves
recommended by the manufacturer, goggles, face
shields, protective clothing, and respirator when
chemicals, bacteria or other toxic or infectious
substances are suspected to be in a drain line.
Drains may contain chemicals, bacteria, and other
substances that may cause burns, be toxic or infec-
tious, or may result in other serious personal injury.
Practice good hygiene. Do not eat or smoke while
handling or operating the tool. After handling or
operating drain cleaning equipment, use hot,
soapy water to wash hands and other body parts
exposed to drain contents. This will help reduce
the risk of health hazards due to exposure to toxic
or infectious material.
Only use the drain cleaner for the recommended
drain sizes. Using the wrong size drain cleaner can
lead to twisting, kinking, or breaking of the cable and
may result in personal injury.
Inspect cable for wear and damage before use.
Replace a worn or damaged cable before using the
drain cleaner.
Do not twist, kink, or over bend cables. Breaking
of the cable may result in serious personal injury.
Inspect the drain to be cleaned before use. If
possible, determine the access point(s) to the drain,
the size(s) and length(s) of the drain, distance to
mainlines, the nature of the blockage, presence of
drain cleaning chemicals or other chemicals, etc. If
chemicals are present in the drain, it is important to
understand the specic safety measures required to
work around those chemicals. Contact the chemical
manufacturer for required information.
If needed, place protective covers in the work
area. The drain cleaning process can be messy.
Place the drain cleaner at a distance no greater
than two feet from drain opening. If the drain
cleaner cannot be placed within two feet from the
drain opening, the drain opening will need to be
extended using a similar size pipe and ttings.
Greater distances can cause control problems leading
to twisting, kinking, breaking or whipping of the cable.
Always wear leather gloves over latex/rubber
gloves to avoid entanglement.
Move the Forward/OFF/Reverse switch to O
(locked) and remove battery from tool before
transporting.
Ensure foot pedal cord is properly wrapped and
the pedal is stored before transporting.
Always clear the area of obstructions before
transporting.
Always secure the tool and any accessories
when operating on uneven or raised surfaces.
Always operate the rotating cable in the F
(forward) direction to clear the blockage. When
freeing the cable from a blockage, do not run in
reverse for more than a few seconds to prevent
cable damage.
Always use common sense and be cautious when
using tools. It is not possible to anticipate every
situation that could result in a dangerous outcome.
Do not use this tool if you do not understand these
operating instructions or you feel the work is beyond
your capability; contact Milwaukee Tool or a trained
professional for additional information or training.
Maintain labels and nameplates. These carry im-
portant information. If unreadable or missing, contact
a MILWAUKEE service facility for a replacement.
WARNING
Some dust created by power sanding,
sawing, grinding, drilling, and other
construction activities contains chemicals known to
cause cancer, birth defects or other reproductive
harm. Some examples of these chemicals are:
lead from lead-based paint
crystalline silica from bricks and cement and other
masonry products, and
arsenic and chromium from chemically-treated
lumber.
Your risk from these exposures varies, depending on
how often you do this type of work. To reduce your
exposure to these chemicals: work in a well ventilated
area, and work with approved safety equipment, such
as those dust masks that are specially designed to
lter out microscopic particles.