Milesight MS-C2963-RPC handleiding

237 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 213 van 237
Milesight Network Camera User Manual | 5 - System Operation Guide | 213
Table 54. Description of the buttons
Parameters Function Introduction
Detection Trigger
Always: in this mode, camera will always detect license plates.
Alarm Input: in this mode, camera will only detect license plates during Alarm
Input is being triggered.
Confidence Level
(Only for LPR1 and LPR2)
You can set the confidence level from 1 to 10.
When the confidence level of the license plate is higher than the set confidence
level, it will push the license plate image to the Smart Search interface.
Repeat Plate Checktime
Set the time interval for repeatedly reading license plates to effectively avoid
duplicate identification of parking vehicles.
You can set Repeat Plate Checktime from 0 to 60min or 0 to 60000ms.