Milesight Network Camera User Manual | 5 - System Operation Guide | 136
Parameters Function Introduction
Main Type There are five main log types: All Type, Event, Operation, Information,
Exception, Event
Sub Type On the premise of main type has been selected, select the sub type to
narrow the range of logs
Start Time The time log starts
End Time The time log ends
Log Export Export the logs
Save Period Set the period of log saving, there are eight options to choose: Permanent
and 30/60/120/180/240/300/360 Days
Go Input the number of logs’ page
5.6 Event
5.6.1 Basic Event
Motion Detection
Step1: Check the checkbox to enable the motion detection;
Note: Currently, the motion detection is only supported in 1O, 1P, and 4R of bundle-stream
mode.
Step2: Select the detection mode;
Step3: Set motion region;