Installation
40
Condensate
If the ducting is to run through cool
rooms or ceiling space, for example, the
significant variations in temperature
between the different areas can cause
condensate to form. Insulate the
ducting to reduce temperature
variations.
If the ducting is to be laid horizontally, it
must be laid with a downwards sloping
gradient of at least ³/₈" (1cm) per
meter. This is to ensure that condensate
cannot drain back into the ventilation
hood.
Miele will not accept warranty claims
for any functional defects or damage
caused by inadequate ducting.
Reducing Collar
(optional accessory)
If you would like to reduce the
environmental impact of your ventilation
system by limiting the CFM output the
Reducing Collar can be installed. It
reduces the air flow to less than
400CFM. Check local building codes
for max. CFM requirements.
Push the Reducing Collar on the
exhaust port of the blower.
Push the exhaust hose over it.
Secure both with a hose clamp.