17
NOTE
The motor in indoor unit will continue running
for about 40 seconds to remove residual heat
when the indoor unit receives a shutdown
command while heating.
If the air conditioner malfunction occurs
because of interferences, please disconnect the
power from the air conditioner, then turn it on
again.
NOTE
When the protective equipment activates,
please shut down the manual power breaker,
and restart operations after the problem is
solved.
NOTE
Do not check or repair the unit on your own.
Please get qualified professionals to conduct any
checks or repairs.
Do not use substances like gasoline, diluent, or
chemical dust cloths to wipe the operations
panel of the controller. Doing so could remove
the surface layer of the controller. If the unit is
dirty, immerse a cloth in diluted and neutral
detergent, wring it out, and then use it to clean
the panel. Lastly, wipe it with a dry cloth.
Ensure that the area is in the open or that it is
adequately ventilated before opening the system
or conducting any hot work. A degree of
ventilation shall continue during the period that
the work is carried out. The ventilation should
safely disperse any released refrigerant and
preferably expel it externally into the
surroundings.
Too much dust and rubbish are stuck to the dust
filter of the indoor unit.
The air outlet of indoor unit is choked.
The air inlet or air outlet of the outdoor unit is
blocked.
Strong wind is Continuously blowing into the air
outlet of the outdoor unit.
2.2.4 Power cuts
2.2.5 Protective feature
2.2.6 Protective equipment
If there is a power outage while the unit is running, the
unit will automatically restart its operation when the
power supply resumes.
If mishandling happens, please disconnect the power
from the system and then reconnect it after a few
minutes.
A
protection feature prevents the air conditioner from
being activated for 3~7 minutes when it restarts
immediately after operation.
This protective equipment will enable the air conditioner
to stop when the air conditioner is forced to run.
The protective equipment may be activated in the
following circumstances:
Cooling
Heating
Mishandling in operation
When the breaker was broken do not use any
unspecified breaker or other wire to replace the
original breaker. The use of electrical wires or
copper wires may cause the unit to malfunction
or cause a fire.
Do not insert your fingers, sticks, or other items
into the air inlet or outlet. Do not remove the fan
mesh cover. When the fan rotates at a high
speed, it could cause bodily injury.
It is very dangerous to check the unit when the
fan is rotating.
Make sure you turn off the main breaker before
any maintenance work begins.
Check the supporting and base structure of the
unit for any damages after a long period of use.
The unit could fall and cause personal injury if
there is any damage.
WARNING
When recycling refrigerant, you must select the
menu to enter the vacuum mode to ensure that
the refrigerant is thoroughly recovered.
If the system is configured with a refrigerant
shut-off device, the refrigerant needs to be
recovered from the maintenance needle valves
of the ODU check valves and the refrigerant
shut-off device respectively. In additioanl,
recycling refrigerant only from the ODU check
valves is also allowed when the system is
powered on and the ODU is without any error
code of Ad1, C21, C26, C28, C2A and EC1.
Systems should be inspected for tightness by a qualified
person. If, during the inspection, it is suspected that
there is a leak, e.g. through refrigerant temperature
checks or capacity reduction, then the location of the
leak shall be identified with suitable detection equipment
and shall be repaired and checked again after the repair
in accordance with national regulations. The results of
the inspection and measures taken afterwards shall be
included in the logbook.
Regular leak tests and inspections shall be carried out
including checking of the safety equipment.
3. MAINTENANCE AND REPAIR
Each refrigerating system shall be subjected to
preventive maintenance in accordance with legal
requirements. The frequency of maintenance depends
on the type, size, age, use, etc. of the system. In many
cases, more than one maintenance service is required in
one year.
The operator of the refrigerating system shall ensure
that the system is inspected, regularly supervised and
maintained.