13. When a FLAMMABLE REFRIGERANT is used, the requirements for installation
space of appliance and /or ventilation requirements are determined according to
-- the mass charge amount (M) used in the appliance,
-- the installation location,
-- the type of ventilation of the location or of the appliance.
14. servicing shall be performed only as recommended by the manufacturer.
15. Unventilated areas
-For appliances containing flammable refrigerants is installed in an unventilated
area, please make sure that it will not stagnate so as to create a fire or explosion
hazard for any refrigerant leak.
16. Qualification of workers
The manual shall contain specific information about the required qualification of
the working personnel for maintenance, service and repair operations. Every
working procedure that aects safety means shall only be carried out by
competent persons:
Examples for such working procedures are:
breaking into the refrigerating circuit;
opening of sealed components;
opening of ventilated enclosures.
1. Checks to the area
3. General work area
4. Checking for presence of refrigerant
5. Presence of fire extinguisher
6. No ignition sources
2. Work procedure
All maintenance sta and others working in the local area shall be instructed on the
nature of work being carried out. work in confined sapces shall be avoided. The area
around the workspace shall be sectioned o. Ensure that the conditions within the
area have been made safe by control of flammable material.
Prior to beginning work on systems containing flammable refrigerants, safety
checks are necessary to ensure that the risk of ignition is minimised. For repair
to the refrigerating system, the following precautions shall be complied with prior
to conducting work on the system.
Works shall be undertaken under a controlled procedure so as to minimise the risk
of a flammable gas or vapour being present while the work is being performed.
The area shall be checked with an appropriate refrigerant detector prior to and
during work, to ensure the technician is aware of potentially flammable atmospheres.
Ensure that the leak detection equipment being used is suitable for use with
flammable refrigerants, i.e. no sparking, adequately sealed or intrinsically safe.
If any hot work is to be conducted on the refrigeration equipment or any
associated parts, appropriate fire extinguishing equipment shall be available to
hand. Have a dry power or CO fire extinguisher adjacent to the charging area.
No person carrying out work in relation to a REFRIGERATING SYSTEM which
involves exposing any pipe work shall use any sources of ignition in such a manner
that it may lead to the risk of fire or explosion. All possible ignition sources, including
cigarette smoking, should be kept suciently far away from the site of installation,
repairing, removing and disposal, during which refrigerant can possibly be released
to the surrounding space. Prior to work taking place, the area around the equipment
is to be surveyed to make sure that there are no flammable hazards or ignition risks.
“No Smoking” signs shall be displayed.
Information on Servicing
Bekijk gratis de handleiding van Midea RSJ-15, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.
Productinformatie
Merk | Midea |
Model | RSJ-15 |
Categorie | Niet gecategoriseerd |
Taal | Nederlands |
Grootte | 4550 MB |