Lighting
LIGHT REPLACEMENT
Replacing the light modules
• The entire light module must be replaced.
• Before changing the light module(s), unplug the appliance or switch off the circuit
breaker in the fuse box.
• Remove the grease filter.
• Disconnect the terminal of LED light.
• Press LED light on the back of the front plate, take the LED light out.
• Replace the lamp.
Max Power Voltage Picture Service Number
Round/Diameter:
2.76"
1.5W DC 12V
17473000000136
Reinstalling the LED Light Module
• Press LED light on the front of front plate, install the LED light on the front plate.
• Connect the terminal of LED light and light leads.
• Reinstall the grease filter.