Handleiding
Je bekijkt pagina 23 van 65

20
When the hob is in the pause mode, all the controls are disable except the ON/OFF , you can
always turn the induction hob off with the ON/OFF control in an emergency. The hob will shut
down after 10min if you don’t exit the pause mode.
• You can pause the heating instead of shutting the hob off.
• When entering the Pause mode, all the controls except the ON/OFF control are disabled.
Pause Mode
Touch the lock/pause control.
Touch the lock/pause control.
All the indicator will show “ 11“
To enter pause mode
To exit pause mode
Power Management Function
• it is possible to set a maximum power absorption level for the induction hob, choosing up to different
power ranges.
• induction hobs are able to limit themselves automatically in order to work at lower power level, to
avoid the risk of overloading.
1. Turn on the hob, then Press at the same time the
“+” (timer) and key lock.
2. The timer indicator will show “ P5“ which
means power level 5。The default mode is on
7.4kW.
To enter Power Management Function
1. Press +/- from the timer.
2. There are 5 power levels, from “P1” to “p5”.
The timer indicator will show one of them.
“P1” : the maximum power is 2.5kW.
“P2” : the maximum power is 3.5kW.
“P3” : the maximum power is 4.5kW.
“P4” : the maximum power is 5.5kW.
“P5” : the maximum power is 7.4kW.
or
To switch to another level
1. Press at the same time + (timer) and key lock
for confirmation.
2. Then the hob will be turned off.
Confirmation and Exit Power Management Function