Midea MG75GQ095AH1B handleiding

72 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 14 van 72
13
Caution
Control handle
Tap
Sealing ring
2. Adjustment of minimum level of the flame.
1. Turn the taps down to minimum.
2. Remove the knob from the tap and place a small
bladed screwdriver in the centre of the Adjustment
screw.
3. The correct adjustment is obtained when the flame has
a length of about 3-4 mm.
- For butane/ propane gas, the adjusting screw must.
- be tightly screwed in.
- Refit the control knob.
4. Repeat this process for each one of the gas taps.
Make sure that the flame does not go out by quickly
turning from maximum flow to minimum flow. If it
does then remove the control knob and make further
adjustments to the gas flow, testing it again once the
adjustment has been made.
Do not dismantle the tap shafe: in the event of a malfunction, change the whole tap.
Before placing the burners back on the top place, make sure that the injector is not
blocked.
A full operational test and a test for possible leakages must be carried out after gas
conversion, (such as soap water or gas detector)
After completing conversion, a qualified technician or installer has to mark “V” on the
right gas category to match with the setting in rating plate. Remove the previous
setting “V” mark.
Adjustment
screw
Warning
Gas Connection
This appliance must be installed and connected in accordance with installa- tion
regulations in force in the country in which the appliance is to be used.
This appliance is supplied to run on LPG and natural gas. Conversion for use on
LPG and natural gases must only be undertaken by a qualified person.

Bekijk gratis de handleiding van Midea MG75GQ095AH1B, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.

Productinformatie

MerkMidea
ModelMG75GQ095AH1B
CategorieFornuis
TaalNederlands
Grootte7029 MB