4 FACTORY PATTEN DETECTION
10
4.1 Service mode
Before entering into service mode, make sure no water remains in the inner
drum, if not, select spin only program to drain them out.
Turn on the machine and take turns [K3] [K5] [K3] [K5] buttons in 10s.
Press [K1] or [K2] to select test program. Press [K7] to confirm your selection and
start the selected test. If you want to go back to test selection interface, press
the [K7] to cancel previous selection.
LED
Display
Check
Target
Check Method
Check Item
t01
Version
switchover
Press [K7] button
LED
displays“xxx
x means current
version
t02
Error code
checking
1. Press [K7] button;
2. Press [K1] to show the next code
and press
[K2] to show the last code ;
3. Press [K3] and [K4] button at the same time
continuously for 3s, all the error code records
deleted, LED displays “E00”.
LED
displays
Exx
x means error code
t03
Version
information
checking
Press [K7] button enter into service mode.
Press [K7] again,
LED displays project number
and version number in turn.
LED displays project
number
and
version number
t05
Drain
-pump
checking
Press [K7] button to drain out all the remaining
water.
If all water drained
out, LED displays
EP”orgod”,
After
20s, i
f there is
still water remains in
it,
LED
displays
FP”or “Err