E10
Step 1
Check the water tap
Step 2
Check the inlet filter
Close the tap and remove the water supply hose. (Fig.2)
Clean the filter with a brush if it is blocked. (Fig.3)
Unscrew the water supply hose from the backside of the machine. Pull out the filter with
long nose pliers. (Fig.4)
Clean the filter with a brush if it is blocked. (Fig.5)
Fig.2 Fig.3 Fig.5Fig.4
Step 3
Check the water inlet valve
Close the tap and disassemble the 2 screws of the top cover plate. (Fig.6)
Push back the top cover plate 15mm until it leave away from the control panel and then
take it down. (Fig.7)
Measure the resistance value of the water inlet valve, 3-6kΩ is OK. (Fig.8)
If the resistance value of the water inlet valve is not well, change the water inlet valve. (Fig.9)
Check the water tap and open it fully if it is not. (Fig.1)
Fig.6 Fig.7 Fig.9Fig.8
Fig.1
14
Check Procedure:
5. MALFUNCTION CODES AND EXPLANATIONS