E50
Malfunction
code
Root Reason Possible cause
E50
Motor inverter
PCB detects
abnormal
signals and
show the error
The external voltage is abnormal, which
causes the motor inverter PCB to judge that
the voltage is too high or too low
The motor inverter PCB is overloaded ->It
may be that the motor rotation is blocked,
causing the motor inverter PCB to overload
The motor inverter PCB is damaged, causing
the motor inverter PCB to detect excessive
current or abnormal IPM temperature
sampling.
The motor inverter PCB is abnormal due to
the main PCB issue. There are the following
situations: 1) The motor speed signal cannot
be detected; 2) Due to the abnormality of
the main PCB, the temperature of the motor
inverter PCB is abnormal, and the motor
temperature is misjudged to be too high; 3)
The motor inverter read the information
(Flash) incorrectly due to the defective motor
inverter PCB.
31
5. MALFUNCTION CODES AND EXPLANATIONS