Step 5
Check the inner wire between PCB and the water level
sensor,well or not
Check Procedure:
① Finding terminals between PCB and the water level sensor .(Fig.14-Fig.15)
② Measuring two vertical terminals that have same color, the resistance value
indicates that the circuit is well.(Fig.16)
③ If the resistance has no value, we need to replace the inner wire.
Step 6
Replace the PCB
① If all the above checks are normal, please change the PCB. (Fig.17)
Fig.14
Fig.17
E12
Fig.15 Fig.16
5. MALFUNCTION CODES AND EXPLANATIONS