Before repairing, use multimeter to judge circuit stand of fail
7 CHECK POINT OF CIRCUIT
28
No Parts Picture Test Description
Parameter
Remarks
1
Water
sensor
Measuring two
vertical terminals
Capacitance value
range 40-50nF-PASS
2
Door
lock
Electrify the
resistance
2 seconds after the
power supply can
automatically locked.
1-2 mins after the
power off can
automatically locked-
PASS
3
Water
valve
measuring
resistance
Resistance value range
3-6KΩ-PASS
4 Pump
Measure the
resistance
Resistance value range
150-250Ω-PASS
5
Heater
measuring
resistance
Resistance value range
20-35Ω-PASS
6 NTC
measuring
resistance
Resistance value range
4.8kΩ±8%@25℃0-
PASS
7 Motor
Measure the
resistance of the
toroids
Resistance value range
1~10Ω-PASS
(Pin1~Pin2~Pin3)
1 2 3