Failure Display and Inspection
Ceramic plate temperature sensor
failure- -short circuit.
Check the connection or replace the ceramic
plate temperature sensor.
Ceramic plate temperature sensor
failure--open circuit.
Reinsert the connection between the display
board and the power board.
Replace the power board.
Zero error.
Ceramic plate temperature sensor
failure.
Wait for the temperature of ceramic plate
return to normal.
Touch “ON/OFF” button to restart unit.
High temperature of ceramic plate
sensor.
Temperature sensor of the NTC
failure--open circuit.
Replace the display board.
Temperature sensor of the NTC
failure--short circuit.
Please inspect whether power supply is
normal.
Power on after the power supply is normal.
Supply voltage is below the rated
voltage.
Supply voltage is above the rated
voltage.
E2
E1
E0
E7
C1
E3
E4
EL
EH
EU
Reinsert the connection between the display
board and the power board.
Replace the power board or the display board.
Communication error.
The hob is equipped with a self diagnostic function. With this test the technician is able to check the
function of several components without disassembling or dismounting the hob from the working
surface.
Failure code occur during customer using & Solution;
No Auto-Recovery
Problem SolutionFailure code