Examples for such working procedures are:
• breaking into the refrigerating circuit;
• opening of sealed components;
• opening of ventilated enclosures.
-No open fire or device like switch which may generate spark/arcing shall be
around unit to avoid causing ignition of the flammable refrigerant used.
Please follow the instructions carefully when storing or maintaining the appliance to
prevent mechanical damage from occurring.
-Do not use means to accelerate the defrosting process or to clean, other than those
recommended by the manufacturer.
-The unit shall be stored in a room without continuously operating ignition sources
(i.e.: open flames, an operating gas appliance) and ignition sources or (i.e.: an
operating electric heater) close to the appli
ance.
-Do not pierce or burn.
-Be aware that the refrigerants may not contain an odor.
1. Transport of equipment containing flammable refrigerants
See transport regulations.
2. Marking of equipment using signs
See local regulations.
3. Disposal of equipment using flammable refrigerants
See national regulations.
4. Storage of equipment/appliances
The storage of the unit should be in accordance with the applicable regulations
or instructions, whichever is more stringent.
5. Storage of packed (unsold) equipment
Storage package protection should be constructed such that mechanical damage
to the unit inside the package will not cause a leak of the refrigerant charge.
The maximum number of pieces of equipment permitted to be stored together
will be determined by local regulations.
6. Infor
mation on servicing
1) Checks to the area
Prior to beginning work on systems containing flammable refrigerants, safety
checks are necessary to ensure that the risk of gnition is minimized. For repair to
the refrigerating system, the following precautions shall be complied with prior to
conducting work on the system.
2) Work procedure
Work shall be undertaken under a controlled procedure so as to minimize the risk
of a flammable gas or vapour being present while the work is being performed.
3) General work area
the nature of work being carried out. Work in confined spaces shall be avoided.
within the area have been made safe by control of flammable material.