10. TIMER: AUTO START/STOP FEATURE:
• Press Timer button, the TIMER ON or TIMER OFF indicator light
illuminates. It indicates the Auto Start or Auto Stop program is
initiated. For some units, keep pressing the Timer button will cancel
the timer settings.
• Press or hold the UP or DOWN button to change the Auto time
by 0.5 hour increments, up to 10 hours,then at 1 hour increments up
to 24 hours. The control will count down the time remaining
until start.
• The selected time will register in 5 seconds, and the system will
automatically revert back to display the previous temperature
setting or room temperature when the unit is on. (when the unit is
o,there is no display.)
• Turning the unit ON or OFF at any time or a djusting the timer
setting to 0.0 will cancel the Auto Start/Stop timed program.
Electronic control operating instructions
11. DISPLAYS:
Shows the set temperature in ” °C" or ” °F" and the Auto-timer
settings.While on Fan only mode, it shows the room temperature.
If the room temperature is too high or low, it will display " HI" or
" LO".
Displays
NOTICE
If the unit breaks o unexpectedly due to the power cut, it will restart
with the previous function setting automatically when the
power resumes.
ADDITIONAL THINGS YOU SHOULD KNOW
Now that you have mastered the operating procedure, here are more features
in your control that you should become familiar with.
• The Cool circuit has an automatic 3 minutes time delayed start if the unit is
turned o and on quickly.
This prevents overheating of the compressor and possible circuit breaker
tripping.The fan will continue to run during this time.
• The control is capable of displaying temperature in degrees Fahrenheit or
degrees Celsius. To convert from one to the other, press and hold the Up and
Down buttons at the same time for 3 seconds.
Error codes:
AS - Room temperature sensor error
ES -Evaporator temperature sensor error
HS -Electric heating sensor error;
CS -Condenser temperature sensor error;
OS -Outside temperature sensor error;
E7 -Unit malfunction.
NOTE:When error occurs,unplug the unit and plug it back in.If error repeats,
call for service.