Handleiding
Je bekijkt pagina 17 van 20

Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.
17
WIRED REMOTE CONTROL
INSTALLATION (Optional and Sold
Separately)
The wired remote controller comes with the following items:
• A set of installation instructions and owner's manuals
• 3 M4X20 Screws to mount on the wall
• 4 wall plugs to mount on the wall
• 2 M4X25 to mount on switch box
• 2 plastic screw bars to fix on switch box
• 1 set of batteries
• 1 set of connecting wires to connect to indoor unit’s main board
Fig. 34 — Wired Controller
To connect the wired remote controller to the indoor units, connect to the
4-pin connector located on the display board.
To connect the wired remote controller to the indoor units:
1. Replace the display board with the shipped with the kit.
2. Install the adapter board (shipped with the kit).
3. Connect the adapter board to the new display board.
Follow the
instructions on the wired controller installation instructions manual for
more details.
4. Connect the female molex plug on the adapter board to the male molex
plug from the extension cable shipped with the kit.
5. Connect the extension cable to the wired controller
For setup instructions, refer to the controller installation manual.
START-UP
Test Operation
Perform a test operation after completing a gas leak and electrical safety
check (see Fig. 35).
Fig. 35 — Test Operation
1. Push ON/OFF on the remote control to begin testing.
NOTE: A protection feature prevents the air conditioner from
activating for approximately 3 to 4 minutes.
2. Push MODE, select COOLING, HEATING, FAN mode to check that
all functions work correctly.
3. To run the test using the MANUAL button on the indoor unit:
a. Open the front panel of the indoor unit;
b. Push MANUAL once to energize the unit. The set conditions
for manual operation are as follows:
•Preset set point: 76
F (24 C)
•Fan speed: AUTO
•Discharge air direction: Pre-set position based on operation in
the COOL or HEAT mode.
4. Set the MANUAL button to OFF (by pushing it twice again) after
completing the test operation.
SYSTEM CHECKS
1. Conceal the tubing where possible.
2. Ensure the drain tube slopes downward along its entire length.
3. Ensure all tubing and connections are properly insulated.
4. Fasten tubes to the outside wall, when possible.
5. Seal the hole through which the cables and tubing pass.
INDOOR UNIT
1. Do all remote control buttons function properly?
2. Do the display panel lights work properly?
3. Does the air deflection louver function properly?
4. Does the drain work?
Explain Following Items To Customer (with the aid of the
Owner’s Manual):
1. How to turn the air conditioner on and off; selecting COOLING,
HEATING and other operating modes; setting a desired temperature;
setting the timer to automatically start and stop the air conditioner
operation; and all other features of the remote control and display
panel.
2. How to remove and clean the air filter.
3. How to set the air deflection louver.
4. Explain care and maintenance.
5. Present the owner’s manual and installation instructions to customer.