16
FINAL TUBING CHECK
IMPORTANT: Ensure the certain factory tubing on the indoor unit has
not shifted during shipment. Ensure the tubes are not rubbing against each
other or any sheet metal. Pay close attention to feeder tubes and ensure
the wire ties on the feeder tubes are secure and tight.
DRAIN CONNECTIONS
Connect the drain line. The drain line must not have a trap anywhere
in its length, must pitch downwards, and must be insulated up to the
outside wall (see Fig. 31). By default, the drain hose is attached to the
left-hand side of unit (when facing the back of the unit). However, it
can also be attached to the right-hand side.
a. To ensure proper drainage, attach the drain hose on the same
side that your refrigerant
piping exits the unit.
b. Attach a drain hose extension (purchased separately) to the end
of the drain hose.
c. Wrap the connection point firmly with Teflon tape to ensure a
good seal and to prevent leaks.
d. For the portion of the drain hose that remains indoors, wrap it
with foam pipe insulation to prevent condensation.
e. Remove the air filter and pour a small amount of water into the
drain pan to ensure that water flows from the unit smoothly.
Plug the Unused Drain Hole
To prevent unwanted leaks, plug the unused drain hole with the rubber
plug provided.
Fig. 31 — Proper Drain Hose Installation
NOTE: For proper orientation of the refrigerant piping,
electrical cable and drain lines, refer to Fig. 32.
Fig. 32 — Bundle drain hose, refrigerant pipes, and
signal cable
NOTE: The factory insulation provided with the product is sufficient,
therefore adding additional insulation to the refrigerant
pipes is NOT recommended. Additional insulation may keep
the product from attaching flush to the wall.
NOTE: For applications where gravity cannot be used for drainage, a
condensate pump accessory is available. Consult the
condensate pump Installation Instructions for more
information.
WIRELESS REMOTE CONTROL
INSTALLATION
Fig. 33 — Wireless Remote Controller
1. Use the two screws supplied with the wireless remote control to attach
the mounting bracket to the wall in a location selected by the customer
and within operating range.
2. Install the batteries in the remote control.
3. Place the remote control into the remote control mounting bracket.
NOTE: For remote control operation, refer to the remote
control’s owners manual.
retaw otni dne niard tup ton oDreporP Do not form a rise
Indoor Unit
Space behind unit
Refrigerant piping
Drain hose
Signal wire
Insulation tape
Swing
Boost
Clean